10.1.4. Field Processing for Each Port Driver
To reduce the processing load, the SS-HQ1 system divides the port driver processing.
Of the 16 ports, four are controlled by individual 1V (fields), and processing for the other 12 is by every 3V
(fields).
Ports processed by 1V each : P0 to P3 (4 ports)
Ports processed by 3V each : P4 to P15 (12 ports)
Fig 10.1-5 Control of Port Drivers
10.1.5. Port Driver Initial Settings, Depending on Presence of EEPROM
Port Driver Initial Settings When EEPROM is Valid
The parameters are initialized by data written in EEPROM.
Port Driver Initial Settings When EEPROM is Invalid
When EEPROM is invalid or not connected, the port drivers function by means of initial values stored in the
CXD3172AR.
Table 10.1-6
Port Driver Initial Settings When EEPROM is Invalid
Port Name
Parameter Name
Category
Description
P0 CAT15_Byte1_bit0
P1 CAT15_Byte1_bit1
P2
AWBMODE
CAT15_Byte1_bit2
AWB mode settings
P3
CRLSON
CAT12_Byte11_bit0
Color rolling control mode
P4
BLCOFF
CAT14_Byte1_bit2
Backlight compensation mode
P5
AEREF
CAT14_Byte1_bit3
AE parameter reference switching
P6
NORMFLC
CAT14_Byte2_bit0
Flicker less mode
P7 AGCMAX
CAT14_Byte1_bit4
AGC
switching
P8 AEME
CAT14_Byte1_bit0 AE/ME
switching
P9
AESHUT
CAT14_Byte1_bit6
AE shutter mode
P10
SGMODE0
CAT17_Byte17_bit0
SGMODE 0-bit switching
P11
GAMSEL
CAT12_Byte7_bit0
Gamma parameter switching
P12 CAT12_Byte1_bit0
P13 CAT12_Byte1_bit1
P14 CAT12_Byte1_bit2
P15
MODESEL
CAT12_Byte1_bit3
DSP operation mode switching
VD
Processing port
0,1,2,3,
4,5,6,7
0,1,2,3,
8,9,10,11
Processing port
Processing port
0,1,2,3,
12,13,14,15