Warning/Error Messages
185
App
end
ix
e
s
If low battery power is detected, or if an error or other abnormal condition occurs on power on or during
operation, the RUN indicator flashes and alarm message flash on the viewfinder, on an external monitor,
and in the subdisplay.
Warning/Error Messages
Warning and Error Messages Related to the Camera Module
Viewfinder screen
Basic status
display
Message
Subdisplay
RUN indicator
Meaning
BATT flashes
BATT flashes
Flashes
Power voltage is low (has reached
the specified NEAR END value).
BATT flashes
BATT flashes
quickly
Flashes quickly
Power voltage is exhausted (has
reached the specified END value).
SHUTDOWN
CAMERA/FAN MAX
The unit must be powered off for
safety. FAN MODE has been
forcibly set to MAX.
OHB FAN NG!
The fan near the CCD has stopped.
MAIN FAN NG!
The fan in the main unit has
stopped.
CAM?
OHB NG!
CCD unit error
CAM?
AD BOARD NG!
AD board error
CAM?
VDA BOARD NG!
VDA board error
CAM?
VPR BOARD NG!
XXXX
VPR board error
VTR ERROR
Error in the VTR module
XXXX: error code
TEMPERATURE
CARE
The temperature inside the unit is
high.
TEMP WARNING/
FAN MAX
The temperature inside the unit has
risen to the limit. FAN MODE has
been forcibly set to MAX.
POWER OFF TO SET
Memory checksum error or other
error occurred.
The unit must be powered off.
CAM ERROR!
POWER OFF->ON
Changing formats or other
operation failed.
The unit must be powered off and
on again.
REF UNLOCK
When REFERENCE on the
<GENLOCK> page of the Camera
>MAINTENANCE menu is set to
GENLOCK IN or AUX IN, an
improper signal was detected.
VTR WARNING
XXXX
Warning in the VTR module
XXXX: error code