Loop tab
Assigns the recording area for each input/output when
using loop recording. The recording loops back to the start
of the loop recording area when it reaches the end of the
area, overwriting the file. If there is more than one file in
the loop recording area, files are overwritten starting with
the oldest file.
Create Loop Recording Area
Remain Area
Displays the remaining area capacity assigned for loop
recording.
Assign Port
Selects the input board to assign a loop recording area.
Assign Area
Specifies the capacity assigned for loop recording for the
corresponding port. Also, the loop recording time is
calculated for display from the specified capacity.
The capacity is specified in 1/16 units of the capacity of the
memory board (2 TB) installed in the unit.
• For one memory board:
1/16, 2/16 to 15/16, 1
• For two memory boards:
1/16, 2/16 to 15/16, 1, 1 + 1/16 to 1 + 15/16, 2
Area Information
Displays the Loop Recording Area numbers for use.
When finished making settings, click the [Submit] button.
The storage is formatted, and the specified capacity and the
loop recording areas are assigned. Click the [Cancel]
button to return to the current settings.
When a loop recording area is specified, all files in
memory are deleted.
Format Loop Recording Area
Deletes the files recorded in the loop recording area of
each port, and then formats the loop recording area. You
can select individual areas to be formatted.
Releasing boundaries of Loop Recording
Area
Deallocates the loop recording area of each port, deleting
the recorded data. You can select individual areas to be
deleted.