7-2.
LD IL Adjustment
Tip
The following describes the adjustment procedure for channel A (OP-0A). To adjust the optical drive system of channel
B (OP-0B), select channel “OP-0B” in step 4 below.
Note
This adjustment cannot be made with the loader assembly removed. Be sure to make this adjustment with the loader
assembly and the cabinet installed (the product status).
Tool
Cartridge (such as PFD23A and PFD50DLA): Commercially available
Note
Abnormal irradiation of the laser during adjustment may damage the disc. Prepare a cartridge that causes no problem
if damaged.
Adjustment procedure
1.
Display the ADJUST window referring to
“7-1-3. Preparation for Adjustment”
.
2.
Place the cursor at “LD IL ADJUST” with the [↑] and [↓] buttons.
3.
Press the [→] button.
DRIVE MAINTENANCE
ADJUST
LD IL ADJUST
㸢㩷㩷㩷㩷
TRK/TLT DRV OFFSET
SKEW
4.
A selection window opens. Select channel “OP-0A” with the [↑] and [↓] buttons and press the [→] button.
DRIVE MAINTENANCE
ADJUST
LD IL ADJUST
TRK/TLT DRV OFFSET
SKEW
SELECT OP
OP-0A
㸢㩷㩷㩷㩷
OP-0B
5.
A confirmation window appears waiting for entry of the [PUSH SET] knob.
LD IL ADJUST
OP-0A
ADJUST START?
OK: SET KEY
EXIT: MENU KEY
PDW-HD1550
7-2
Содержание PDW-HD1550
Страница 1: ...PROFESSIONAL DISC RECORDER PDW HD1550 SERVICE MANUAL 1st Edition Revised 2 ...
Страница 12: ......
Страница 52: ...Hold the shaded portions Keep away a screwdriver Objective lens Actuator PDW HD1550 1 40 ...
Страница 54: ......
Страница 90: ......
Страница 102: ...Menu hierarchy M2 SERVICE SUPPORT M23 OPTION KEY STATUS INSTALL REMOVE PDW HD1550 4 12 ...
Страница 207: ...4 Install the removed parts by reversing the steps of removal PDW HD1550 6 47 ...
Страница 224: ......
Страница 252: ......
Страница 275: ......
Страница 276: ...PDW HD1550 SY PDW HD1550 CN E 9 878 590 03 Sony Corporation Printed in Japan 2018 8 08 2014 ...