Connections and Settings
Ch
apt
er 3 Prep
ara
tio
ns
For details of HDW-M2000/M2000P settings, refer to the
HDW-M2000/M2000P Operation Manual.
Connections for pool coverage
The following figure shows an example of connections for
pool coverage, with the PDW-700 Professional Disc
Camcorder connected.
HDW-M2000 (recorder)
setting
Settings on this unit
REMOTE 1 (9P) button:
Unlit
Remote control switch:
REMOTE
Setup menu item 214
REMOTE INTERFACE: 9PIN
75
Ω
coaxial cable (not supplied)
To SDI OUT 1 connector
PDW-700
PDW-HD1550 (this unit)
To SD/HDSDI INPUT
connector
PDW-700 (camcorder)
setting
Settings on this unit
HDSDI REMOTE I/F on
page CAM CONFIG 1 of
the MAINTENANCE menu:
other than OFF
Remote control switch:
REMOTE
Setup menu item 214
REMOTE INTERFACE: SDI