29
Connections and Settings
Chapt
er
3
Pre
para
tio
ns
Editing control unit settings
When connecting an editing control unit (BVE-700/700A/
2000) to use with this unit, set VTR constants as follows.
.
HDW-M2000 (recorder) settings
BVE-700/700A (editing control unit) setting Settings on this unit
REMOTE 1 (9P) button: Lit
SYNCHRONIZE menu: OFF
Remote control switch:
REMOTE
REF.VIDEO INPUT connector 75
Ω
termination
switch: OFF
Setup menu item 214
REMOTE INTERFACE:
9PIN
Audio selection function switching button
INPUT button: HDSDI
Function menu HOME >F1 (VID. IN): SDI
Function menu page 1 >F1 (TCG): INT
Function menu page 1 >F2 (PR/RGN): PRESET
Function menu page 1 >F3 (RUN): FREE
System frequency
VTR constant
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
59.94i/59.94P/29.97P
A0
9C
00
96
07
07
03
80
0A
07
FE
00
80
5A
FF
5A
50i/50P/25P
A1
9C
00
7D
07
07
03
80
0A
07
FE
00
80
4C
FF
4B
23.98P
A2
9C
00
78
07
07
03
80
0A
07
FE
00
80
48
FF
48