192
Connection Examples of a Multipoint Connection
• For a multipoint connection, only the Communication System with the
PCSA-MCG106/MCG109 HD MCU software installed can be used as main terminal.
If you want to use multiple Communication Systems as main terminals depending on
the type of connection, the same number of HD MCU software as that of main
terminals is required to install.
• When a system is constructed using only PCS-XG100/XG100S terminals and
PCS-XG77/XG77S terminals on which the PCSA-RXG77 HD Upgrade Software is
installed, 1080p60 (Full HD) progressive video signals with a resolution of 1920 ×
1080 can be sent from the main terminal to the other terminals.
Installing the optional PCSA-MCG106/MCG109 HD MCU software on two
HD Visual Communication Systems enables cascade connection with two
main terminals. The PCSA-MCG106 software allows you to connect to up to
10 points by connecting four points to each main terminal. The
PCSA-MCG109 software allows you to connect to up to 16 points by
connecting seven points to each main terminal.
• Even if the PCSA-MCG106/MCG109 HD MCU software is installed in three or more
Communication Systems, cascade connection is not available.
• For cascade connection, “Broadcast Mode” can be set to “Voice Activate” mode only
during communication. The “Split” and “Split (fixed)” modes are not available.
• Control of the remote camera and switching of the remote image input is not possible
during cascade connections.
• Only the PCS-XG100/XG100S/XG77/XG77S is enabled for use as a main terminal
on the remote site.
Notes
Using the Cascade Connection via LAN (Up to 16 Points)
Notes
Main terminal
Main terminal
The illustration shows an example of when PCSA-MCG109 is installed.