![Sony ODS-D280F Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/sony/ods-d280f/ods-d280f_service-manual_401402056.webp)
Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
200
–
○
1 sec.
A TDMA area error was detected during write-back to the re-
cording disc or formatting.
201
–
○
1 sec.
A disc error was detected during finalizing of the recording disc.
300
○
○
1 sec.
The physical format of the recording disc is restoring.
2-1-5.
Error 6X, Error 8X
When an error is detected relating to a startup operation or relating to an adjustment before writing, one of the following
error codes is displayed.
Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
60
E65
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-0A. (On side 0)
EE5
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-0B. (On side 0)
F65
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-1A. (On side 0)
FE5
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-1B. (On side 0)
61
000
○
○
1 sec.
Depletion of OPC area in the disc was detected.
6C
000
○
○
0.25 sec.
Other error was detected during startup.
6D
000
○
○
1 sec.
The time is coming to replace the cartridge.
001
○
○
1 sec.
This media can not be used. For more details, contact your local
Sony Sales Office/Service Center.
6F
E00
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-0A. (On side 0)
E03
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-0A. (On
side 0)
E80
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-0B. (On side 0)
E83
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-0B. (On
side 0)
F00
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-1A. (On side 0)
F03
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-1A. (On
side 0)
F80
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-1B. (On side 0)
F83
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-1B. (On
side 0)
80
E65
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-2A. (On side 1)
EE5
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-2B. (On side 1)
F65
○
○
0.25 sec.
An abnormal value was detected in the measurement of eccen-
tricity in the optical block assembly Ch-3A. (On side 1)
Continued
ODS-D280U/ODS-D280F
2-8
Содержание ODS-D280F
Страница 4: ......
Страница 9: ...Frame Wiring 10 3 Revision History ODS D280U ODS D280F 5 ...
Страница 10: ......
Страница 12: ......
Страница 42: ...Hold the shaded portions Keep away a screwdriver Objective lens Actuator ODS D280U ODS D280F 1 30 ...
Страница 158: ......
Страница 238: ......
Страница 248: ...Possible cause A cartridge is remaining in the unit ODS D280U ODS D280F 6 4 ...
Страница 274: ......
Страница 278: ......
Страница 300: ......
Страница 304: ......
Страница 306: ......
Страница 307: ......