1-17. Flexible Flat Cable and Coaxial Cable
1-17-1. Disconnecting/Connecting Flexible Flat Cable
Note
• Be very careful not to fold flexible flat cables. Life of flexible flat cable will be significantly shortened if it is
folded.
• Each flexible flat cable has conductive side and insulated side. If the flexible flat cable is connected in the wrong
orientation of the conductive side and the insulated side, the circuit will not function.
• Check that the conductive side of the flexible flat cable is not contaminated.
• Do not open the locking tab excessively at an angle above the value shown in the figure to prevent the connector
from being damaged.
Locking tab
Locking tab
Connector
Insulating surface
90˚
0˚ to 20˚
Flexible flat cable
Flexible flat cable
90˚
Type A
Angle of locking tab and
angle of connecting-disconnecting flexible flat cable
120˚
Locking tab
120˚
Flexible flat cable
Locking tab
Connector
Flexible flat cable
Insulating
surface
Type B
Angle of locking tab and
angle of connecting-disconnecting flexible flat cable
Locking tab
0˚
Flexible flat cable
90˚
Angle of locking tab and
angle of connecting-disconnecting flexible flat cable
Locking tab
Connector
Type C
Flexible flat cable
(Upper and lower both sides
are conductive surface.)
90˚
Disconnecting
1.
Turn off the power.
2.
Slide or lift up the locking tab in the direction of the arrow to unlock and pull out the flexible flat cable.
ODS-D280U/ODS-D280F
1-34
Содержание ODS-D280F
Страница 4: ......
Страница 9: ...Frame Wiring 10 3 Revision History ODS D280U ODS D280F 5 ...
Страница 10: ......
Страница 12: ......
Страница 42: ...Hold the shaded portions Keep away a screwdriver Objective lens Actuator ODS D280U ODS D280F 1 30 ...
Страница 158: ......
Страница 238: ......
Страница 248: ...Possible cause A cartridge is remaining in the unit ODS D280U ODS D280F 6 4 ...
Страница 274: ......
Страница 278: ......
Страница 300: ......
Страница 304: ......
Страница 306: ......
Страница 307: ......