USO
RESTRITO
582
Cross-Point Settings (Xpt Assign Menu)
Knob
Parameter
Adjustment
Setting values
1
Table No
Selection of the
table to be set
1 to 14
Knob
Parameter
Adjustment
Setting values
2
Button No Cross-point button
selection
1 to 300
Knob
Parameter
Adjustment
Setting values
3
V/K Pair
No
Selection of video
and key pair
number to be
assigned
1 to 300
Ch
a
p
te
r 19
Co
n
tr
o
l P
a
n
e
l S
e
tu
p
(P
a
n
e
l)
1
In the Panel >Xpt Assign menu, press [Table Button
Assign].
The Table Button Assign menu appears.
The table number appears on the upper left part of the
status area.
The left part of the status area shows the cross-point
button numbers, video and key pair numbers, video
signal source names and source numbers, and key
signal source names and source numbers. When the
shift button is pressed, the number column is
distinguished by color.
The right part shows the video and key pair numbers,
and the names of video signals and key signals set in
the main table.
The Table Button Assign menu also allows you to
access the Main, V/K Pair Assign menu and the Src
Name/LCD Color menu.
2
Using the knob, select the table number.
3
Using any of the following methods, select the button
number.
•
Press an auxiliary bus control block cross-point
button.
The auxiliary bus control block is in selection mode,
only when the menu for cross-point button selection
is showing.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knob.
4
Using any of the following methods, select the pair
number.
•
Press directly on the list in the status area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knob.
5
Using the buttons in the <Button Assign> group,
assign the selected pair number to the button number
currently selected in table 1.
Set:
Delete the signal currently assigned to the
selected button number and make a new
assignment.
Insert:
Move down one line the signal currently
assigned to the selected button number and
following signals, and make a new assignment.
Notes
When a button number upper than 121 is selected,
execution of “Insert” is impossible. The signal
assignments to button numbers upper than 121 cannot
be changed. When “Insert” is executed for any other
number, moving down of signals ends at number 120,
and the signals assigned to numbers upper than 121 are
maintained in their original lines.
To disable a button
In the Panel >Xpt Assign >Table Button Assign menu,
select the button you want to disable, and press [Inhibit].
To delete any currently assigned signal
In the Panel >Xpt Assign >Table Button Assign menu,
select the button corresponding to the signal you want to
delete, and press [Delete] in the <Button Assign> group.
The signal assigned to the button number next to the
selected button number and following signals move up one
line.
Notes
When a button number upper than 121 is selected,
execution of “Delete” is impossible. The signal
assignments to button numbers upper than 121 cannot be
changed. When a signal assigned to any other button
number is deleted, moving up of signals ends when the
signal assigned to number 120 has moved to number 119,
and the signals assigned to numbers upper than 121 are
maintained in their original lines.
Returning the table to its default state
1
In the Panel >Xpt Assign >Main, V/K Pair Assign
menu or Panel >Xpt Assign >Table Button Assign
menu, press [Default Recall].
A confirmation message appears, asking whether or
not to return to the default state.
2
To return to the default state, press [Yes], and to cancel
the operation, press [No].
Setting the cross-point button shift
operation
You can set the operation of the rightmost button in each
row of cross-point buttons excluding the reentry buttons.
Содержание MVS-8000X SystemMVS-7000X System
Страница 358: ...USO RESTRITO 358 Wipe Pattern List Appendix Volume 1 Enhanced Wipes Rotary Wipes ...
Страница 360: ...USO RESTRITO Random Diamond DustWipes 360 1 w pe PaternLO ...
Страница 362: ...USO RESTRITO 362 DME Wipe Pattern List Appendix Volume 1 Door 2D trans 3D trans ...
Страница 363: ...USO RESTRITO DME Wipe Pattern List 363 Appendix Volume 1 Flip tumble Frame in out Picture in picture ...
Страница 364: ...USO RESTRITO 364 DME Wipe Pattern List Appendix Volume 1 Page turn Page roll ...
Страница 365: ...USO RESTRITO DME Wipe Pattern List 365 Appendix Volume 1 Mirror Sphere Character trail Wave Ripple Split slide ...
Страница 367: ...USO RESTRITO DME Wipe Pattern List 367 Appendix Volume 1 Squeeze 3D trans Picture in picture Page turn ...
Страница 376: ...USO RESTRITO 376 Menu Tree Appendix Volume 1 Frame Memory Menu FRAME MEM button Color Bkgd Menu COLOR BKGD button ...
Страница 377: ...USO RESTRITO Menu Tree 377 Appendix Volume 1 AUX Menu AUX button CCR Menu CCR button ...
Страница 379: ...USO RESTRITO Menu Tree 379 Appendix Volume 1 DME Menu DME button ...
Страница 380: ...USO RESTRITO 380 Menu Tree Appendix Volume 1 Global Effect Menu GLB EFF button Router Menu Device Menu DEV button ...
Страница 381: ...USO RESTRITO Menu Tree 381 Appendix Volume 1 Macro Menu MCRO button ...
Страница 382: ...USO RESTRITO 382 Menu Tree Appendix Volume 1 Key Frame Menu KEY FRAME button ...
Страница 383: ...USO RESTRITO Menu Tree 383 Appendix Volume 1 Effect Menu EFF button ...
Страница 384: ...USO RESTRITO 384 Menu Tree Appendix Volume 1 Snapshot Menu SNAPSHOT button ...
Страница 385: ...USO RESTRITO Menu Tree 385 Appendix Volume 1 Shotbox Menu SHOTBOX button ...
Страница 386: ...USO RESTRITO 386 Menu Tree Appendix Volume 1 File Menu FILE button ...
Страница 388: ...USO RESTRITO 388 Menu Tree Appendix Volume 1 ENG SETUP button to previous page topages after 390 to next page ...
Страница 389: ...USO RESTRITO Menu Tree 389 Appendix Volume 1 ENG SETUP button to page 387 to previous pages to following pages ...
Страница 390: ...USO RESTRITO 390 Menu Tree Appendix Volume 1 ENG SETUP button to previous pages to next page a MVS 7000X only ...
Страница 391: ...USO RESTRITO Menu Tree 391 Appendix Volume 1 ENG SETUP button to previous pages ...
Страница 392: ...USO RESTRITO 392 Menu Tree Appendix Volume 1 User Setup Menu USER SETUP button Diagnostic Menu DIAG button ...
Страница 413: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...
Страница 706: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...