20
Setting Signal Formats
Pre
par
at
ion
Setting Signal Formats
Setting the Signal Format
You can set the signal format and the input reference signal
format of each device that is automatically detected.
The combinations of signal formats and input reference
signals that can be configured are as follows.
1
Display the menu.
a
Open the Engineering Setup >System >Format
menu (7313).
2
Set the formats.
Format menu
a
Press [Signal Format].
b
Press the button for the desired format to set in the
pop-up window.
3
Set the input reference signal.
a
In the <Ref Input Format> group, select the input
reference signal.
Tri Sync:
Tri-level sync for an HD system
BB:
Black burst or sync
This setting is available for HD systems only.
If [BB] is selected, you can set the signal format
conversion in the format converter (when MKS-6550
Format Converter Board is installed). If [Tri Sync] is
selected, the format converter cannot be used.
For details about format converter settings and
operations, refer to the User’s Guide.
4
Apply and save the settings.
a
Press [Execute].
Signal format
System
Signal format
Field frequency
Effective number
of scan lines
SD system
50
576i
59.94
480i
HD system
50
720P
59.94
50
1080i
59.94
23.976
1080PsF
24
Input reference signal
Signal format
(HD system)
Input reference signal
Tri Sync BB
720P/50
–
Black Burst 50
Sync 50
720P/59.94
59.94
Black Burst 59.94 Sync 59.94
1080i/50
50
Black Burst 50
Sync 50
1080i/59.94
59.94
Black Burst 59.94 Sync 59.94
1080PsF/23.976 47.952
–
1080PsF/24
48
–
Notes
Memo
Signal Format
Ref Input Format
Execute