12-4 Items in the Extended Setup Menu
Menu items in the range 600 to 650, relating to the time code generator (Continued)
602
VITC POSITION SEL-2
In 525-line mode
Select a line to insert the VITC in.
12H ... 18H ... 20H:
Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
In 625-line mode
Select a line to insert the VITC in.
9H ... 21H ... 22H:
Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
Item number
Item name
Settings
603
ID CODE PRESET
Select whether or not to set the ID code.
off :
Do not set the ID code.
on:
Set the ID code.
To set the ID code:
Press the F5 (SET) button with this menu item displayed in the menu display, to
enter the ID code setting mode. You can then set the user ID digit by digit using
the
T
and
t
buttons for digit selection. When all required digits have been set
correctly, press the F5 (SET) button again to save the ID code and exit from the
ID code setting mode.
604
ID CODE SW
Select whether or not to record the ID code set using item 603 in the user bits.
off :
Record the normal data in the user bits.
on:
Record the ID code in the user bits.
605
TCG REGEN MODE
Select the signals to be regenerated when the time code generator is in the
regeneration mode (i.e., when the function menu item TCG (F2) is set to
REGEN).
TC&UB :
Both the time code and user bit signals are regenerated.
TC:
Only the time code signal is regenerated.
UB:
Only the user bit signal is regenerated.
606
TC OUTPUT SIGNAL IN
REGEN MODE
Select the signal output from the TIME CODE OUT connector during normal (
×
1)
speed playback in the following cases:
• For tape playback when the function menu item TCG (F1) is set to INT and TCG
(F2) set to REGEN.
• For preroll or postroll playback during automatic editing with the tape.
TAPE:
During tape playback, the playback time code signal is output without
regeneration. (The time code values do not correspond to the video output.)
REGEN :
The playback time code is output after regeneration.
AUTO:
Can be selected with MSW SY software version 4.0 and later.
The operation with the AUTO setting is as follows.
• The playback timecode (LTC) signal is output delayed, to coincide with the
output video signal.
• Operation is independent of the internal timecode generator settings or editing
state.
• The output video signal and LTC are only accurately synchronized for normal
speed playback.
• If the edit preset is turned on or off, the delay changes, and therefore the
timecode will be discontinuous.
(Continued)