Chapter 12
Setup Menus
Chapter 12
Setup Menus
12-9
Menu items in the range 100 to 199, relating to the control panels (Continued)
109
Item number Item name
Settings
FORCED EE WHEN
TAPE UNTHREAD
During tape threading and unthreading, and when no cassette is inserted, select
whether the setting of the function menu item PB/EE controls the PB/EE setting
for output signals.
off:
Control by the function menu item PB/EE
on :
No control (always E-E signal)
When a digital cassette is inserted and the function menu item PB/EE is set to
EE, select the VTR modes in which input video and audio signals are
automatically handled in E-E mode.
When an analog cassette is inserted, regardless of the function menu setting the
PB mode is always selected.
S/F/R :
In STOP/EJECT/F.FWD/REW modes
STOP:
In STOP/EJECT modes
107
REC INHIBIT LAMP
FLASHING
Select whether or not to flash the REC INHI indicator when the function menu
item RECINH is set to OFF and the record inhibit plug on the cassette is pressed
in.
off :
Do not flash the REC INHI indicator.
on:
Flash the REC INHI indicator.
108
AUTO EE SELECT
111
TSO PLAY
Select whether or not to enable tape speed override mode.
DIS :
Disable tape speed override mode.
TSO:
Enable tape speed override mode.
FEED:
Enable feed play mode.
115
PHASE LOCK IN
VARIABLE X3 (except
MSW-2000)
Select whether or not to lock the capstan phase in
×
3 variable speed play mode
when playing back a Betacam or Betacam SP cassette.
off :
Do not lock.
on:
Lock.
116
JOG DIAL RESPONSE
Select the tape speed characteristics for the search dial rotation rate (VTR
commands).
TYPE1 :
Tape speed varies linearly over the range –1 to +1.
TYPE2:
Tape speed varies stepwise as shown in the figure below
a)
over the
range –3 to +3. (Characterized by a zone around –1 and +1 where the tape
speed is independent of the search dial rotation rate)
TYPE3:
Tape speed varies linearly over the range –3 to +3, as shown in the
figure below
b)
.
TYPE4:
Tape speed varies stepwise as shown in the figure below
c)
over the
range –2 to +2. (Characterized by a zone around –1 and +1 where the tape
speed is independent of the search dial rotation rate)
117
CONTROL PANEL
SELCTION
Select the control panel function when the PANEL SELECT switch on the switch
panel is set to REAR.
SW :
Only the control panel connected to the CONTROL PANEL connector on
the connector panel functions.
PARA :
The control panels connected to the CONTROL PANEL connectors on
the switch panel and connector panel both function.
a)
b)
c)
+3
+1
-1
-3
FWD
FWD
RVS
RVS
+3
-3
FWD
FWD
RVS
RVS
+2
+1
-1
-2
FWD
FWD
RVS
RVS
Speed
(reverse)
Rotation rate
TYPE 2
TYPE 3
TYPE 4
Speed
Speed
Rotation rate
Rotation rate
(forward)
(Continued)