3. Camera Operations: Technical Menu
89
Technical >
Network
Makes settings related to the network.
Menu item
Setting
Description
Subnet Mask (DHCP/On:
obtain automatically
, DHCP/
Off:
255.255.255.0
)
Enter the subnet mask of the unit.
Enabled when DHCP is set to Off.
[Note]
Configurable only when Network Mode is set to
Station.
MAC Address
Displays the MAC address of the wireless LAN
adaptor connected to the unit.
Regenerate Password (Run/
Cancel)
Regenerates the password (execute by
selecting Run).
[Note]
Executable only when Network Mode is set to Access
Point.
Technical >
Alerts & Tally
Makes settings related to the REC button and media capacity alerts.
Menu item
Setting
Description
Rec Light
On
/Off
Turns the REC lamp on/off.
Rec Start/Stop Beep
0
to 99
Adjusts the volume of the beep sound
emitted when recording starts and stops.
Media Near Full
Alarm
1min/3min/
5min
Sets the alarm threshold for notification that
the remaining media is low.
Technical >
Batt./Voltage Alarm
Makes settings related to batteries and external DC power supply voltage alarms.
Menu item
Setting
Description
Near End:Info Battery
5%
to 100% (5% increments)
Sets the threshold value at which the
remaining battery capacity indicator starts
flashing when using a Sony Info battery.
End:Info Battery
0%
to 5%
Sets the threshold value for displaying the
“Battery End” warning when using a Sony Info
battery.
Near End:Sony
Battery
11.5V
to 17V (0.1V increments)
Sets the threshold value at which the
remaining battery capacity indicator starts
flashing when using a Sony non-Info battery.
End:Sony Battery
11.0V
to 12.5V (0.1V
increments)
Sets the threshold value for displaying the
“Battery End” warning when using a Sony
non-Info battery.
Near End:Other
Battery
11.5V to 17V (
11.8V
) (0.1V
increments)
Sets the threshold value at which the
remaining battery capacity indicator starts
flashing when using a non-Sony battery.
Technical >
Batt./Voltage Alarm
Makes settings related to batteries and external DC power supply voltage alarms.
Menu item
Setting
Description
End:Other Battery
11.0V
to 14V (0.1V increments)
Sets the threshold value for displaying the
“Battery End” warning when using a non-Sony
battery.
Detected Battery
Sony Info Battery/Sony
Battery/Other Battery/DC IN
(12V)/DC IN (24V)
Displays the result of automatic battery pack
type detection.
DC Low Voltage1
11.5V
to 17V (0.1V increments)
Sets the threshold value for displaying a low
voltage warning when using an external
power source connected to the DC IN
connector.
DC Low Voltage2
11.0V
to 14V (0.1V increments)
Sets the threshold value for displaying an
undervoltage warning when using an external
power source connected to the DC IN
connector.
DC(24V) Low
Voltage1
22.5V
to 34.0V (0.1V
increments)
Sets the threshold value for displaying a low
voltage warning when using a 24 V external
power source connected to the DC IN
connector.
DC(24V) Low
Voltage2
22.0V
to 28.0V (0.1V
increments)
Sets the threshold value for displaying an
undervoltage warning when using a 24 V
external power source connected to the DC IN
connector.
Technical >
Panel Control
Makes settings related to the displays.
Menu item
Setting
Description
Brightness level
High
/Mid/Low/Minimum
Adjusts the brightness of the sub display and
mini display.
Lock Operator Side
without Rec Button
/
without Assign3 Button /
without Rec/Assign3 /
with Rec/Assign3 Button
Sets whether to lock the REC button or
Assign3 button operation when buttons are
locked using the LOCK switch on the Operator
side.
Lock Assistant Side
without Rec Button
/
with Rec Button
Sets whether to lock the REC button operation
when buttons are locked using the LOCK
switch on the Assistant side.