![Sony MG40 Series Скачать руководство пользователя страница 125](http://html.mh-extra.com/html/sony/mg40-series/mg40-series_command-reference-manual_411003125.webp)
(E)
4-37
MG40 Series
Gateway address
Th
is function is used to set and acquire the Ethernet gateway address.
Th
e gateway address setting is refl ected the next time the equipment is started up.
Set
Setup
mode
Ethernet
The command sets the Ethernet gateway address.
Command format
NGW=<Address>
<Address>
1.0.0.1 to 223.255.255.254 (excluding 127.x.x.x)
(Factory setting: 192.168.1.1)
Return format
Execution results
Target
MG41 main unit
Save setting values
Setting values saved. (Th
e setting values are saved at the same time as the setting
command is executed.)
Examples of use
Transmission :
NGW=192.168.1.1
Return
:
OK000
Compatible command
None
Acquire
Setup
mode
Ethernet
Measurement
mode
The command acquires the gateway address.
Command format
NGW?
Return format
NGW=<Address>
<Address>
1.0.0.1 to 223.255.255.254
Target
MG41 main unit
Examples of use
Transmission :
NGW?
Return
:
NGW=192.168.1.1
Compatible command
None