![Sony MG40 Series Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/sony/mg40-series/mg40-series_command-reference-manual_411003121.webp)
(E)
4-33
MG40 Series
Command response
Th
is function is used to set whether or not the execution results are to be returned in response to each
command.
Even when it is set to “no response,” the response to the CRP command itself is returned.
Set
Setup
mode
Ethernet
CC-Link
The command sets whether to return the execution results in response to each command.
Command format
CRP=<Value>
<Value>
0 : No response
1 : Response (Factory setting)
Return format
Execution results
Target
MG41 main unit
Save setting values
Setting values saved.
Examples of use
Transmission :
CRP=0
Return
:
OK000
Transmission
:
CRP=1
Return
:
OK000
Compatible command
None
Acquire
Setup
mode
Ethernet
CC-Link
Measurement
mode
The command acquires whether or not the execution results are to be returned.
Command format
CRP?
Return format
CRP=<Value>
<Value>
0 : No response
1 : Response
Target
MG41 main unit
Examples of use
Transmission :
CRP?
Return
:
CRP=1
Compatible command
None