23
You can configure the capture range on the MAS-A100 setup screen. Noise can be
reduced by reducing the audio capture range of MAS-A100 units that are close to
noise sources to match the movement of the lecturer.
Room acoustic characteristics
It is recommended to use a room with low reverberation and low reflection acoustic
characteristics. In an environment with reverberation or reflection, the intelligibility of
the sound may be poor and the sound quality may make hearing difficult.
Measures to prevent general audio issues (use of sound absorbing material, curtains,
diffuser on flat surfaces, etc.) are effective.
4.3. Network design
This section describes the design of networks for use with the MAS-A100 system.
It describes the network function of the MAS-A100, power supply using PoE, and the
specifications required for the network switch.
MAS-A100 network function overview
The MAS-A100 connects to a network using a single LAN cable (Cat 5e or higher), but
internally it has two network interfaces.
Each network interface has a separate MAC address.
Also, the IP address must be different for each network interface.
The name and functions of the two network interfaces are shown below.
Network interface MAC address
IP address
Function
Network interface for
setup
MAC address for
setup
IP address for setup
IPv6 address for setup
MAS-A100 setup
and operation
Network interface for
Dante
MAC address for
Dante
IP address for Dante
Dante audio output
and setup