Sending Images to FTP Server — FTP client Menu
67
Note
In the case that the synchronized preset position is
specified in
Position at alarm
in the Preset position
menu, an alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always:
Alarm detection is always effective.
Schedule:
You can specify the period during which
alarm detection is effective.
Click
Schedule
and the menu for the effective period
is displayed. (“Setting the Schedule — Schedule
Menu” on page 80)
Alarm buffer
Select
Use alarm buffer
to forward the image/audio at
a specified time before or after alarm detection (pre-
alarm, post-alarm).
If you do not select the alarm buffer, only the image at
the moment of alarm detection is forwarded.
Click
Alarm buffer
to display the Alarm buffer menu.
For details, see “Setting the Alarm Buffer — Alarm
buffer Menu” on page 81.
Note
When Edge Storage is enabled, the Alarm buffer is not
available.
OK/Cancel
See “Buttons common to every menu” on page 31.
Periodical sending Tab — Setting
the periodical FTP client activity
You can set to send image files (JPEG files) to an FTP
server periodically.
Periodical sending
Select
On
when you want to use periodical sending.
Remote path
Type the remote path using up to 64 characters.
Image file name
Type the file name of the image sent to the FTP server
using up to 10 alphanumeric characters, - (hyphen) and
_ (under score).
The actual image file name will be the specified image
file name with a suffix and extension .jpg.
Note
You cannot send an audio file using periodical sending
of the FTP client function.
Suffix
Select a suffix to be added to the file name sent to the
FTP server.
None:
The name of the sent file will be the image file
name.
Date & time:
The date & time suffix is added to the
image file name.
The date & time suffix consists of the year (2 digits),
month (2 digits), date (2 digits), hour (2 digits),
minute (2 digits) and second (2 digits), and
sequential number (2 digits), thus adding a 14-digit
number to the image file name.
Sequence number:
A sequential number of 10 digits
between 0000000001 and 4294967295 and two fixed
digits 00 are added to the image file name.
Sequence number clear
Click
Clear
to reset the
Sequence number
suffix to 1.
Mode
Select the periodical sending mode.
Periodical mode:
An image file is sent periodically
according to the specified
Interval
and
Effective
period
.
Tour mode:
An image file is sent each time the camera
is moved to a preset position during the tour.
Note
Periodical mode
and
Tour mode
are not available on
the SNT-EP104 and SNT-EP154.
Interval
Type the interval at which you want to send images to
the FTP server periodically. You can set the hour (H),
minutes (M) and seconds (S) between 1 second and 24
hours (one day).
Note
The actual interval may be longer than the set value,
depending on the image size, image quality setting, bit