![Sony ipela SNC-RS84P Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/sony/ipela-snc-rs84p/ipela-snc-rs84p_user-manual_418091077.webp)
A
d
mini
s
tra
ting
t
he
Came
ra
Sending an Image via E-mail — e-Mail (SMTP) Menu
77
Alarm sending Tab — Setting the
e-mail sending mode when
detecting the alarm
Set to send an e-mail linked with alarm detection by the
external sensor input or by the built-in detection
functions.
Alarm sending
Select
On
to set sending an e-mail linked with alarm
detection.
File attachment
Set whether an image file (JPEG file) is to be attached to
the e-mail or not.
When
On
is selected, the image file made using the
settings below is attached. When
Off
is selected, only
the message is sent.
Image file name
Type the file name you want to assign to the image to be
attached to an e-mail. You can use up to 10
alphanumeric characters, - (hyphen) and _ (underscore)
for naming.
Suffix
Select a suffix to be added to the file name.
None:
No suffix is added. The image file name is
assigned to the image to be sent via e-mail.
Date & time:
The date & time suffix is added to the
image file name.
The date/time suffix consists of lower two-digits of
the year (2 digits), month (2 digits), date (2 digits),
hour (2 digits), minute (2 digits), second (2 digits),
and sequential number (2 digits), thus adding 14-
digit number to the image file name.
Sequence number:
A sequential number of 10 digits
between 0000000001 and 4294967295 and two fixed
digits 00 are added to the image file name.
Sequence number clear
Click
Clear
to reset the
Sequence number
suffix to 1.
Alarm
Select the alarm to be linked with e-mail notification.
Sensor input 1:
The external sensor that is connected to
sensor input1 of the camera I/O port.
Sensor input 2:
The external sensor that is connected to
sensor input 2 of the camera I/O port.
Sensor input 3:
The external sensor that is connected to
sensor input 3 of the camera I/O port.
Sensor input 4:
The external sensor that is connected to
sensor input 4 of the camera I/O port.
Tampering:
An alarm that is triggered when the camera
detects tampering, such as direction shift or spraying.
VMF:
An alarm of the VMF detection function.
Motion detection:
The alarm detected by the motion
detection function.
Click
Detection
, and the motion detection menu is
displayed to allow you to set the motion detection
function (page 94).
Audio detection:
Select the preset position linked with
alarm by audio detection function.
Click
Detection
, and the audio detection menu is
displayed to allow you to set the audio detection
function (page 94).
Note
In the case that the synchronized preset position is
specified in
Position at alarm
in the Preset position
menu, an alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always:
Alarm detection is always effective.
Schedule:
You can specify the period during which
alarm detection is effective.
Click
Schedule
and the menu for the effective period
is displayed. (“Setting the Schedule — Schedule
Menu” on page 93)
OK/Cancel