![Sony Ipela SNC-CS50N Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/sony/ipela-snc-cs50n/ipela-snc-cs50n_user-manual_418026091.webp)
Ot
her
s
Pin assignment of I/O port
91
<string> position. The maximum length of <string>
is 255 characters.
4)
enaAuthTraps=<value>
Set the case value of “mib-2.snmp.snmp
EnableAuthenTraps.0” in the <string> position.
Type “1” (enable) or “2” (disable) in the <value>
position.
5) community=<ID>,r,
<communityName>,<IpAddressString>
Set the community attributes. <ID> describes the
setting identification number (1 to 8),
<communityName> describes the community
name to be set, and <IpAddressString> describes
the IP address of the host you allow access (0.0.0.0
for any host).
Example:
To allow reading by any host in the “private”
community and having the ID number “2”.
community=2,r,private,0.0.0.0
6)
trap=<ID>,<communityName>,
<IpAddressString>
Set the attributes to send traps to. <ID> describes
the setting identification number (1 to 8),
<communityName> describes the community
name to send traps to, and <IpAddressString>
describes the IP address of the host to send traps to.
Example:
To specify the destination of traps as the
public community and the ID number “1”.
trap=1,public,192.168.0.101
7)
delcommunity=<ID>
This parameter is used to delete the previous
community setting. <ID> describes the community
setting identification number (1 to 8).
8)
deltrap=<ID>
This parameter is used to delete the previous setting
of the host to send traps to. <ID> describes the trap
setting identification number (1 to 8).
When you have finished changing the SNMP setting
information using the above parameters 1) to 8), check
the changed settings using an inquiry commands. If the
changed settings are OK, restart the SNMP using the
following CGI command.
SNMP restart command
<Method>
GET, POST
<Command>
Pin assignment of I/O
port
Using the I/O receptacle
While holding down the button on the slot to which you
want to connect the wire (AWG No. 28 to 22) with a
small slotted screwdriver, insert the wire into the slot.
Then release the screwdriver from the button.
Repeat this procedure to connect all required wires.
Pin No.
Pin name
1
Sensor In 1 +
2
Sensor In 1– (GND)
3
Sensor In 2 +
4
Sensor In 2 – (GND)
5
Alarm Out 1 +
6
Alarm Out 1 –
7
Alarm Out 2 +
8
Alarm Out 2 –
9
GND
10
GND
11
RS232C · RX
12
RS232C · TX
121110 9 8 7 6 5 4 3 2 1
I / O
12 11 10 9
8 7 6 5 4
3 2 1
I / O
12 11 10 9
8 7 6 5 4
3 2 1
1
2
Slotted
screwdriver
Wire