Owner’s Record

The model number is located at the rear and the serial number is located inside the battery
compartment. Record the serial number in the space provided below. Refer to these numbers
whenever you call upon your Sony dealer regarding this product.

Model No. ICD-P110/P210

Serial No.

Step 1: Installing the Batteries

Slide and lift the battery
compartment lid.

Insert two LR03 (size AAA)
alkaline batteries with
correct polarity, and close the
lid.

1

2

Clock setting display appears when you insert batteries for the first time, or
when you insert batteries after the unit has been without batteries for a certain
period of time. Please refer to Steps 2 to 3 in “Step 2: Setting the Clock” to set the
date and time.

Replacing the batteries

The battery indicator on the display
window shows the battery
condition.
When 

 flashes, replace the

batteries with new ones.
When 

 flashes, the batteries are

exhausted and the unit will stop
operation.

Battery life*

With continuous use, approx. 7.5
hours recording/5 hours playback in
the HQ mode, and approx.15.5 hours
recording/8.5 hours playback in the
SP and LP modes is possible.
* Using Sony alkaline batteries LR03

(size AAA)

* When playing back through the

internal speaker with the medium
volume level

The battery life may shorten
depending on the operation of the
unit.

`

Notes

• Do not use manganese batteries for

this unit.

• When you replace the batteries,

insert the new ones within 3
minutes after you removed the
exhausted ones. Otherwise, the
display may show the clock setting
display or incorrect date and time
when you reinsert the batteries. In
this case, set the date and time
again.
The recorded messages and alarm
setting, however, will remain.

• When replacing the batteries, be

sure to replace both batteries with
new ones.

• Do not charge dry batteries.
• When you are not going to use the

unit for a long time, remove the
batteries to prevent damage from
battery leakage and corrosion.

• The unit is accessing data while

“ACCESS“ appears in the display
window. Or, the OPR indicator
flashes in orange. While accessing,
do not remove the batteries. Doing
so may damage the data.

Clock setting display appears when you insert batteries for the first time, or when you insert battery after the unit has been
without battery for a certain period of time. In this case, proceed from step 2.

Display the clock setting display.

Set the date.

2

Press 

Nx

PLAY/STOP.

The month digits will flash.

3

Set the month and day in sequence,
then press 

Nx

PLAY/STOP.

The hour digits will flash.

1

2

Press – 

.

 or 

>

+ to display “SET

DATE”.

3

Press 

Nx

PLAY/STOP.

The year digits will flash.

Tip

To set the date to Year 2004, display
“04Y”.

2

Step 2: Setting the Clock

Set the time.

3

3

Set the minute.

4

Press 

Nx

PLAY/STOP at the time

signal.

The display will return to “SET
DATE”.

5

Press MENU to exit from the menu
mode.

If the unit is left unused for more
than 3 seconds in the stop mode, the
display will show the current time .

Recording Messages

You can record up to 99 messages in each of the four folders (A, B, C, and D).
Since a newly recorded message is automatically added behind the last recorded
message, you can start recording quickly without searching for the end of the
last recording.

Note

Before making a long recording, be sure to insert new batteries and check the battery
indicator.

Select the recording mode.

For how to select the recording mode, see “Changing the
Recording Mode” on the reverse side.

Select the folder.

Start recording.

You do not need to keep pressing 

zX

REC/PAUSE while recording.

1

Press 

zX

REC/PAUSE.

Stop recording.

If you do not change the folder after you stop recording, the next time you
record you will record in the same folder.

To

Do this

pause recording*

Press 

zX

REC/PAUSE.

During recording pause, the OPR indicator flashes in
red and “PAUSE” flashes in the display window.

release pause and

Press 

zX

REC/PAUSE.

resume recording

Recording resumes from that point.
(To stop recording after pausing recording, press

x

STOP.)

listen to the current

Press 

x

STOP to stop recording, then press

recording

Nx

PLAY/STOP.

review the current

Press 

Nx

PLAY/STOP during recording.

recording instantly

select the microphone

You can select the microphone sensitivity by

sensitivity

setting MIC SENS.
HIGH: To record at meeting or in a quiet and/or
spacious place.
LOW: To record for dictation or in a noisy place.

* About one hour after you pause recording, recording pause is automatically released

and the unit goes into the stop mode.

4

3

e.g.

Press 

x

STOP.

The unit stops at the
beginning of the current
recording.

B

Basic Operations

* The display selected

with the DISPLAY
button appears.

Information

IN NO EVENT SHALL SELLER BE LIABLE FOR ANY DIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY
NATURE, OR LOSSES OR EXPENSES RESULTING FROM ANY
DEFECTIVE PRODUCT OR THE USE OF ANY PRODUCT.

For the customers in the U.S.A.

INFORMATION

This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules.  These limits are designed to provide reasonable
protection against harmful interference in a residential
installation.  This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur
in a particular installation.  If this equipment does cause
harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and

receiver.

– Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected.

– Consult the dealer or an experienced radio/TV technician

for help.

You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.

If you have any questions about this product, you may call:
Sony Customer Information Services Center 1-800-222-7669 or
http://www.sony.com/

Declaration of Conformity

Trade Name:

SONY

Model:

ICD-P110/P210

Responsible Party:

Sony Electronics Inc.

Address:

16450 W. Bernardo Dr, San Diego, CA
92127 U.S.A.

Telephone Number: 858-942-2230
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:  (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.

Precautions

On power

• Operate the unit only on 3 V DC. Use two LR03 (size AAA)

alkaline batteries.

On safety

• Do not operate the unit while driving, cycling or operating

any motorized vehicle.

On handling

• Do not leave the unit in a location near heat sources, or in a

place subject to direct sunlight, excessive dust or mechanical
shock.

• Should any solid object or liquid fall into the unit, remove

the batteries and have the unit checked by qualified
personnel before operating it any further.

On noise

• Noise may be heard when the unit is placed near an AC

power source, a fluorescent lamp or a mobile phone during
recording or playback.

• Noise may be recorded when an object, such as your finger,

etc., rubs or scratches the unit during recording.

On maintenance

• To clean the exterior, use a soft cloth slightly moistened in

water. Do not use alcohol, benzine or thinner.

If you have any questions or problems concerning your unit,
please consult your nearest Sony dealer.

Backup recommendations

To avoid potential risk of data loss caused by accidental
operation or malfunction of the IC recorder, we
recommend that you save a backup copy of your recorded
messages on a tape recorder or to a computer, etc.

Current folder

Press FOLDER to
display the folder in
which you wish to
record messages.

Note on recording

Noise may be recorded if an object,
such as your finger, etc., accidentally
rubs  or scratches the unit during
recording.

Maximum recording time

The maximum recording time of all
the folders is as follows.  You can
record messages for the maximum
recording time in a single folder.

ICD-P110

ICD-P210

HQ*

1 h. 40 min. 3 h. 35 min.

SP**

4 h. 35 min. 9 h. 40 min.

LP***

7 h. 35 min. 15 h. 45 min.

(h.: hours/min.: minutes)
* HQ: High quality recording mode

(monaural sound)

** SP: Standard play recording mode

(monaural sound)

***LP: Long play recording mode

(monaural sound)

Notes

• To record in better sound quality,

select the HQ mode.  For switching
the recording mode, see “Changing
the Recording Mode” on the reverse
side.

• Before making a long recording, be

sure to check the battery indicator.

• The maximum recording time and

the number of messages you can
make varies depending on the
conditions of use.

• When you record messages in the

mixture of HQ, SP and LP mode, the
maximum recording time will be
between those for the HQ and LP
modes.

Remaining memory
indication

During recording, the remaining
memory indicator decreases one by
one.

When the remaining time of
recording reaches  5 minutes, the
last one of the indication flashes.
If the remaining recording time
display mode is selected,
“REMAIN” will also flash when the
remaining time reaches 1 minute.
When the memory is full, recording
automatically stops and “FULL”
will flash in the display window
with an alarm sound. To continue
recording, first erase some of the
messages.

Notes

• If you press 

zX

REC/PAUSE when

the memory is full, “FULL” will flash
with an alarm sound. Erase some of
the messages before you start
recording again.

• If you press 

zX

REC/PAUSE after

you have recorded 99 messages,
“FULL” will flash with an alarm
sound. Select another folder or erase
some of the messages.

Starting recording
automatically in response
to the sound — Advanced
VOR function

When VOR (voice operated
recording) is set to ON in the menu,
recording starts when the recorder
detects sound. (“VOR” is displayed
in the display window.)

Recording stops when no sound is
heard. (“VOR PAUSE” flashes in
the display window.)

Note

VOR function is affected by the sound
around you.  Set the MIC SENS to
HIGH or LOW. If recording is not
satisfactory after you have changed
the microphone sensitivity, or for
important recording, set VOR to OFF.

Flashing

* The display selected with the DISPLAY button appears (see the reverse side).

When playing back a previously recorded message, start from Step 1.
When playing back a message you have just finished recording, start from Step 3.

Select the folder.

Select the message number.

1

Press FOLDER to display
the folder you wish to
play back.

Press – 

or 

>

+ to

display the desired
message number.

>

+: for larger

message number

– 

.

: for smaller

message number

Current folder

Counter
display*

Playing Back Messages

Start playback.

After playing back one message, the unit stops at the beginning of the next
message. When the continuous play function is set to “ON” (see the reverse
side), the unit stops after playing all messages in a folder.
When the last message on a folder has been played back, the unit stops at the
beginning of the last message.

For private listening

Connect an ear receiver or headphones (not supplied) to the EAR jack. The built-
in speaker will be automatically disconnected. If noise is heard, wipe the
headphones plug.

Other operations

To

Do this

stop at the current position

Press 

Nx

PLAY/STOP or 

x

STOP.

To resume playback from that point,
press 

Nx

PLAY/STOP again.

go back to the beginning

Press – 

once. *

of the current message

skip to the next  message

Press 

>

+

 

once.*

go back to previous

Press – 

.

 or 

>

+

 

repeatedly.

messages/skip to succeeding

(During stop mode, keep the button

messages

pressed to skip the messages
continuously.)

* These operations are for when EASY-S (Easy Search function) of the menu is set to

“OFF”.

3

2

 Adjust the volume

with VOL +/– .

EAR jack

1

 Press 

Nx

PLAY/STOP.

B

Getting started

Troubleshooting

Before taking the unit for repair, check the following
sections.  Should any problem persist after you have
made these checks, consult your nearest Sony dealer.

The unit does not operate.

• The batteries have been inserted with incorrect

polarity.

• The batteries are weak.
• The buttons are locked with the HOLD switch. (If

you press any button, “HOLD” will flash three
times.)

No sound comes from the speaker.

• The ear receiver or headphones are plugged in.
• The volume is turned down completely.

“FULL” is displayed and you cannot start
recording.

• The memory is full. Erase some of the messages.
• 99 messages has been recorded in the selected

folder. Select another folder or erase some of the
messages.

Noise is heard.

• An object, such as your finger, etc., accidentally

rubbed or scratched the unit during recording so
that noise was recorded.

• The unit was placed near an AC power source, a

fluorescent lamp or a mobile phone during
recording or playback.

• Plug of the connected microphone was dirty when

recording. Clean the plug.

• Ear receiver/headphones plug is dirty. Clean the

plug.

Recording level is low.

• Slide MIC SENS to “HIGH”.

Recording is interrupted.

• The advanced VOR function is activated.  Set VOR

to “OFF”.

Recording level is unstable (when recording
music, etc.).

• This unit is designed to automatically adjust the

recording level when recording meetings, etc., and
is not suitable for music recording.

“--Y--M--D” or “--:--” is displayed.

• You have not set the clock.

“--Y--M--D” or “--:--” is displayed on the REC
DATE display.

• The date and time of recording will not be

displayed if you recorded the message when the
clock was not set.

You cannot divide a message.

• You cannot divide a message in a folder which has

99 messages.

• If you divide messages frequently, the unit may

become unable to divide a message.

• You cannot divide a message in the first or the last

1 second of a message.

You cannot record messages up to the
maximum recording time.

• If you record messages in a mixture of HQ, SP and

LP modes, the recordable time varies from the
maximum HQ mode recording time to the
maximum LP mode recording time.

• No more recording can be made when 99 messages

each have been recorded in a folder.

• Due to the limitation of the IC recording system,

this unit records in the minimum recording unit. If
the length of each message cannot be divided by
the minimum recording unit, the remaining
recording time may decrease by more than the
total length of the messages.

The remaining time displayed in the display
window is shorter than that displayed in
the supplied “Digital Voice Editor“ software.

• The unit requires a certain amount of memory for

system operation. That amount is subtracted from
the remaining time, which is the reason for the
difference.

The unit does not operate correctly.

• Take out the battery and insert it again.

Please note that recorded messages may be erased
during service or repair work.

2

Counter display (or the
selected display mode)

x

STOP

zX

REC/PAUSE

Current message
number

Counter display*

Tip

This unit does not have a power on/off
switch.  The display is shown at all
times.

Playing back a message
repeatedly
— Repeat Play

During playback, press

Nx

PLAY/STOP for more than

one second.

“ will be displayed and the

selected message will be played
back repeatedly.
To resume normal playback, press

Nx

PLAY/STOP again. To stop

playback, press 

x

STOP.

Playing back all messages
in a folder continuously
— Continuous Play

You can select the continuous play
mode with the CONT in the menu.
When you set CONT to ON, you
can play back all messages in a
folder continuously.

Searching forward/
backward during playback
(Cue/Review)

To search forward, keep 

>

+

pressed during playback and
release the button at the point you
wish to resume playback.
To search backward, keep – 

.

pressed during playback and
release the button at the point you
wish to resume playback.

If you keep 

>

+ or – 

.

pressed,

the unit starts to search at higher
speed.
During cue/review, the counter
will be displayed, regardless of the
display mode setting.

1

Tip

When fast playback is done to the end
of the last message,  “END” flashes 5
times. (You cannot hear the playback
sound.) If you keep – 

.

 pressed

while “END” is flashing, the messages
are played back rapidly, and normal
playback will start at the point you
release the button.
When “END” stops flashing and the
OPR indicator goes off, the unit will
stop at the beginning of the last
message.
If the last message is long and you
wish to start playback at a later part of
the message, keep 

>

+ pressed to

play back the message to the end and
then press – 

.

 while “END” is

flashing to go back to the desired
point .
(For messages other than the last one,
go to the beginning of the next
message and play backward to the
desired point.)

Locating quickly the point
you wish to start playback
(Easy Search)

When EASY-S is set to “ON” in the
menu, you can quickly locate the point
you wish to start playback by pressing
– 

.

 or 

>

+

 

repeatedly during

playback or playback pause.
You can go back approx. 3 seconds by
pressing –

.

 once, or advance

approx. 10 seconds by pressing 

>

+

once.  This function is useful when
locating a desired point in a long
recording. For details, see “Locating
quickly the point you wish to start
playback (Easy Search)” on the
reverse side.

1

Press MENU to enter the menu
mode.

1

Press – 

.

 or 

>

+ to select

the digits of the year.

1

Press – 

.

 or 

>

+ to select

the digits of the hour.

2

Press 

Nx

PLAY/STOP.

The minute digits will flash.

2

Speak to the
built-in
microphone.

OPR indicator

(lights in red during
recording.)

Message 1

Message 2

Blank space

Newly recorded message

OPR indicator

(lights in green during
playback.)

The memory is
nearly full.

2

Remaining memory
indicator

Selected message number

Number of
messages in
a folder

Recording mode

If the battery compartment lid is
accidentally detached,  attach it as
illustrated.

Make sure to insert both
of the batteries from
their – ends.

1

Nx

PLAY/STOP

Printed on 100% recycled
paper using VOC (Volatile
Organic Compound)-free
vegetable oil based ink.

GB-UC/CEP110/P210.p65

9/24/04, 2:12 AM

1

Отзывы: