6-67
HVR-M15J/M15U/M15N/M15E/M15P/M15C
7.
Record of Use Check
Page 7
Address 90 to 95, A4 to AF, C8 to CD
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (VD-036 board BT1001) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Address
90
91
92
93
94
95
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
C8
C9
CA
CB
CC
CD
Function
Eject count with tape
Count (H)
Count (M)
(BCD code)
Count (L)
Eject count without
Count (H)
tape
Count (M)
(BCD code)
Count (L)
Power supplying
Hour (H)
time
Hour (M)
Hour (L)
(BCD code)
Minute
Drum rotation
Hour (H)
counted time
Hour (M)
Hour (L)
(BCD code)
Minute
Tape run time
Hour (H)
Hour (M)
Hour (L)
(BCD code)
Minute
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Remarks
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
After setting the clock, set the date of power on next
Using method:
1) The record of use data is displayed at page: 7, addresses: 90 to
95, A4 to AF, C8 to CD.
Initializing method:
Order Page Address Data
Procedure
1
7
01
7F
2
7
02
FF
3
7
00
01
Press PAUSE (Write) button.
4
7
02
Check the data changes to
“01”.
5
7
01
00
6
7
02
00
Содержание HVR M15U - Professional Video Cassete recorder/player