NETWORK SETTINGS menu
Page name
Page No.
Item
Settings
Indication
<TCP/IP SETTING>
N01
IP ADDRESS
0.0.0.0
to 255.255.255.255
IP address setting
SUBNET MASK
0.0.0.0
to 255.255.255.255
Subnet mask display
DEFAULT GATEWAY
0.0.0.0
to 255.255.255.255
Default gateway display
SET
ENTER to execute
A “SET OK?” message is displayed. Press ENTER
again to confirm the change.
<LAN SETTINGS>
N02
AUTO NEGOTIATION
ON
, OFF
Auto negotiation on/off of connection speed and
communication mode with connected device
CONNECTION
SPEED
10M,
100M
Connection speed selection
10M: 10BASE-TX
100M: 100BASE-TX
Configurable only when AUTO NEGOTIATION is off.
DUPLEX MODE
HALF,
FULL
Communication method selection
HALF: Half-duplex communication
FULL: Full-duplex communication
Configurable only when AUTO NEGOTIATION is off.
LINK CONDITION
(DOWN), (UP)
Communication mode display (read only)
(DOWN): Not connected correctly
(UP): Connected successfully
SET
ENTER to execute
A “SET OK?” message is displayed. Press ENTER
again to confirm the change.
<CNS SETTINGS>
N03
CNS MODE
LEGACY
, BRIDGE, MCS
Network connection mode selection
LEGACY: External controller connected using CCA-5
cable only
BRIDGE: External controller connected using
point-to-point LAN cable
MCS: (MCS mode operation available only when the
multi-camera control system support software is
installed.) Multi-camera system configuration of
multiple network-capable devices. Requires 1
MSU-1000/1500 Master Setup Unit in the system as
master device
CCU NO
Default:
0
When CNS MODE is LEGACY or BRIDGE:
1 to 96, A to Z
When CNS MODE is MCS: 1 to 24
MASTER IP
ADDRESS
0.0.0.0
to 255.255.255.255
Displayed only when the multi-camera control system
support software is installed.
<NETWORK RESET>
N04
ALL RESET
ENTER to execute
A “NET SETTINGS RESET OK?” message is
displayed. Press ENTER again to reset NETWORK
SETTINGS menu items to factory default values.