133
Menu List
A
ppen
dix
Items Relating to Digital Processing (Nos. 902 to ...)
Item number
Item
Setting
Function
902
FREEZE MODE
[field]
field1
field2
2
1
Specifies the freeze (still-picture) mode and freeze timing
during manual freezing (by REMOTE 1-IN(9P) or REMOTE
2 PARALELL I/O(50P) connector or on the control panel) or
automatic freezing.
field: Freezes the odd or even field, depending on the
timing in freeze mode.
field1: Freezes the first (odd) field
field2: Freezes the second (even) field
2: Freezes the first and the subsequent second
field
1: Freezes the second field and the subsequent
first field
In the case of freezing in playback modes other than
normal playback, the picture is frozen in frame mode only
when dynamic tracking is performing a frame operation.
The picture is frozen in field mode when dynamic tracking is
not operating.
The frozen picture does not change even if you change this
setting during freeze mode. The change to this setting
becomes effective the next time this unit outputs a still
picture.
When the stop freeze function is enabled, regardless of the
setting of this item, the picture is frozen in frame mode only
when dynamic tracking is performing a frame operation, or
is frozen in field mode when dynamic tracking is performing
a field operation or when it is not operating.
903
FREEZE CONTROL
FROM KEY PANEL
[momentary]
latch
Determines the freeze operation control by button
operations.
momentary: The picture is frozen only while the button is
held down.
latch: The picture is frozen when the button is pressed, and
remains frozen when the button is released.
The frozen picture is cancelled when the button is pressed
again.
Button operations
Freezing in odd or even (first or second) field is specified
by item 902. Distinction between the first or second field,
follows the distinction in the reference signal.
905
STOP FREEZE
CONTROL
disable
[enable]
Enable or disables the stop freeze function.
911
ACTIVE LINE 1080
CONVERT MODE
1035
k
1080(PANEL)
Selects the conversion mode of the effective scanning line
number.
1035
k
1080(CONV): Convert the effective scanning line
number from 1035 to 1080 preserving the aspect ratio
of the image.
1035
k
1080(PANEL): Convert the effective scanning line
number from 1035 to 1080. The 1035 lines of the
image are inserted into the 1035 lines of 1080 lines,
then it is horizontally compressed.
Note
This setting is valid only for HDCAM playback when the
optional HKSR-5001 is installed.
Содержание HDCAM-SR SRW5100