128
MANUAL RPN
The MANUAL RPN menu is used for manual RPN compensation. For details, refer to “5-6-2. Manual RPN Compensation
Adjustment”.
RPN MANAGE
The RPN MANAGE menu is used for RPN compensation setting and management. For details, refer to “5-6-4. Performing
Automatic RPN Detection Effectively”.
OHB-ADJ1
The OHB_ADJ1 menu is used for adjustment of the CMOS block. For details, refer to “5-3-1. Sensitivity Adjustment”.
<MANUAL RPN>
S03 TOP
RPN CH SELECT
:
R
RPN CURSOR
:
OFF
CURSOR H POS.
:
1006
CURSOR V POS.
:
575
CURSOR JUMP
:
CURR
RECORD RPN
:
EXEC
DELETE RPN
:
EXEC
MONITOR SEL
: YPbPr
<RPN MANAGE>
S04 TOP
RPN ALL PRESET : EXEC
AUTO CONCEAL : EXEC
APR AT ABB : ON
<OHB-ADJ1>
S05 TOP
1080/59.94i
[R1] [G1] [B1]
GAIN_CONT: 80 80 - 80
[R2] [G2] [B2]
GAIN_CONT: 80 80 - 80
FILTER : ON
MONITOR SEL : YPbPr
STORE FILE : EXEC