2
HCD-NEZ3/NEZ5
1.
NEW/FORMER TYPE DISCRIMINATION
New/former type can be distinguished in the version display mode
of the test mode.
Procedure:
1. Press the
I
/
1
button to turn the power on.
2. While pressing the
[DSGX]
button, press the
l
m
button
and turn the
[VOLUME]
knob in the counter-clock wise.
3. When this mode is activated, model and destination is displayed
on the fluorescent indicator tube.
4. Press the
[DSGX]
button to display software version and year,
month, day of the software creation display mode.
Former type : ####V1XX
New type
: ####V2XX
(#### :release date of software, XX :revision of version)
5. To release this mode, while pressing the
x
button, press
the
I
/
1
button and turn the
[VOLUME]
knob in the counter-
clock wise.
•
Method to Distinguished by Serial No.
The set since serial No. of the following table is new type.
Model
Destination
Serial No.
US
Since 8259876
Canadian
Since 4119759
HCD-NEZ3
AEP
Since 5147808
UK
Since 6126228
East European and Russian
Since 7120201
AEP
Since 5130981
HCD-NEZ5
UK
Since 6103836
East European and Russian
Since 7109341