
80
Five-digit display
C:21:
ππ
C:22:
ππ
C:31:
ππ
C:32:
ππ
E:61:
ππ
E:62:
ππ
C : 21: 00
STBY
40min
40min
Cause and/or corrective actions
• Moisture condensation has occurred.
m
Remove the cassette and leave the camcorder for at least 1 hour.
(p. 71)
• The video heads are dirty.
m
Clean the heads using the Sony DVM12CL cleaning cassette (not
supplied). (p. 71)
• A serviceable situation not malfunctioned above has occurred.
m
Remove the cassette and insert it again, then operate the
camcorder. (p. 10)
m
Disconnect the power cord of the AC power adaptor or remove
the battery pack. After reconnecting the power source, operate
the camcorder.
• A camcorder malfunction which you cannot service has occurred.
m
Contact your Sony dealer or local authorized Sony service
facility and inform them of the five digits. (example: E:61:10)
Self-diagnosis function
If you are unable to resolve the problem, contact your Sony dealer or local authorized Sony service
facility.
The camcorder has a self-diagnosis display.
This function displays the camcorder’s
condition with five digits (a combination of a
letter and figures) on the LCD screen or in the
viewfinder. If this occurs, check the following
code chart. The five-digit display informs you
of the camcorder’s current condition. The last
two digits (indicated by
ππ
) will differ
depending on the state of the camcorder.
LCD screen/viewfinder
Self-diagnosis display
•C:
ππ
:
ππ
You can service the camcorder
yourself.
•E:
ππ
:
ππ
Contact your Sony dealer or local
authorized Sony facility.
Содержание Handycam Vision DCR-TRV5
Страница 92: ...Sony Corporation Printed in Japan ...