1-1
ENGLISH
ENGLISH
HDR-SR1/SR1E_L2
1. SERVICE NOTE
1-1. POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4 V), the power is shut off so
that the unit cannot operate.
These following method is available to prevent this.
Method:
Use the AC power adaptor (AC-L15A).
1-2. USING SERVICE JIG
1. Connect the extension cable (J-6082-352-A) between CN4006 on the MD-133 board and CN1005 on the VC-456 board.
2. Connect the extension cable (10P, 0.5 mm) (Note) between CN4015 on the MD-133 board and CN1012 on the VC-456 board.
Note:
Cut off the extension cable (18P) (J-6082-393-1) to make the extension cable of 10 pins.
MD-133 board (side A)
VC-456 board (side B)
Extension cable (100P)
(J-6082-352-A)
Extension cable (10P)
(Note)
CN4015
CN1012
CN4006
CN1005