1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-CX6EK/CX7/CX7E/CX7K/CX7EK_L2
1-5. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by execution of “Clear All record-data”.
Note:
For “Clear All record-data”, refer to Service Manual, ADJ (“6. Record Data” of “3-2. SERVICE MODE”).
1-4-5. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Check that R1846 in the periphery of IC1803 on the VC-493 board is 0
Ω
and energizes. If it is not energizes, replace the R1846.
When R1846 is 0
Ω
and energizes, replace the lens block (Note).
3
Check that no error occurs, after replacing the lens block and performing the necessary adjustment. If an error occurs, inspect
the camera control circuit (IC1803 of VC-493 board) periphery.
Note:
When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld
operation.