12
KD-30XS955/34XBR960/34XS955/36XS955
KD-30XS955/34XBR960/34XS955/36XS955
1-4.PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock,
discharge CRT before attempting to remove the anode cap. Short between anode and CRT
coated earth ground strap.
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to
remove the anode cap. After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT.
NOTE: After removing the anode cap, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield or carbon
painted on the CRT.
REMOVAL PROCEDURES
a
b
Anode Button
c
Turn up one side of the rubber cap in
the direction indicated by arrow a .
Use your thumb to pull the rubber
cap fi rmly in the direction indicated
by arrow b .
When one side of the rubber cap separates from
the anode button, the anode cap can be removed
by turning the rubber cap and pulling it in the
direction of arrow c .
HOW TO HANDLE AN ANODE CAP
1. Do not use sharp objects which may cause damage to the surface of the anode
cap.
2. To avoid damaging the anode cap, do not squeeze the rubber covering too
hard. A material fi tting called a shatter-hook terminal is built into the rubber.
3. Do not force turn the foot of the rubber cover. This may cause the shatter-hook
terminal to protrude and damage the rubber.
1. Remove the Sub-Woofer Assemblies.
2. Discharge the anode of the CRT and remove the
anode cap.
3. Unplug all interconnecting leads from the defl ection
yoke, neck assembly, degaussing coils and CRT
grounding strap.
4. Remove the CX Board from the CRT.
5. Remove the chassis assembly.
6. Loosen the neck assembly fi xing screw and remove.
7. Loosen the defl ection yoke fi xing screw and remove.
8. Place the set with the CRT face down on a cushion
and remove the degaussing coil holders.
9. Remove the degaussing coils.
10. Remove the CRT grounding strap and spring tension
devices.
11. Unscrew the four CRT fi xing screws [located on each
CRT corner] and remove the CRT
[Take care not to handle the CRT by the neck].
Coated
Earth
Ground
Strap
5
9
6
4
11
8
1
3
7
10
2
Содержание FD Trinitron WEGA Hi-Scan KD-34XS955
Страница 96: ...96 KD 30XS955 34XBR960 34XS955 36XS955 KD 30XS955 34XBR960 34XS955 36XS955 BLOCK DIAGRAMS 3 OF 3 ...
Страница 215: ......
Страница 219: ......
Страница 222: ...15 SETUP Setup SETUP SETUP SETUP SETUP Rear Panel 3 4 1 2 5 6 7 8 9 q qa qs ...
Страница 253: ......
Страница 299: ......
Страница 317: ......
Страница 329: ......
Страница 333: ......
Страница 342: ......
Страница 347: ...13 SETUP Setup SETUP SETUP SETUP SETUP Rear Panel 3 4 1 2 5 6 7 8 9 q qa ...
Страница 378: ......
Страница 428: ......