2-3
DSR-80/80P/60/60P
2-7. RACK MOUNTING
The unit can be mounted in a 19-inch standard rack.
It is recommended to use the following kit.
Rack Mount Kit
: RMM-130
(optional accessory)
or
RACK-MOUNT SLIDES : MODEL 305
slide length 22 inch
(ACCURIDE)
Note for rack mounting :
.
When several VTRs are mounted in a rack, it is
recommended to install a fan for ventilation. Good air
circulation is essential to prevent internal heat build-up
in a rack (
+
5
d
C to
+
40
d
C must be met for all units).
.
Never remove an upper panel and lower panel during
rack mounting.
.
Be sure to secure the rack to the floor to avoid accidents
when a unit is pulled out.
.
Connect long enough cables on the connector panel,
considering that the unit is pulled out.
.
This equipment can use with two tiers.
But with three tiers and more, keep the spaces between
the each VTRs in the rack 1 unit (about 44 mm) or more.
1. Remove the four screws on right and left side panels.
And install the Inner Members of the rails to the right
and left side panels with the screws removed.
2. Install the Outer Member Brackets of the slide rails to
the rack. Adjust the distance from the edge of the slide
rail to the outside of the rack so that it meets the
required specification.
Inner memeber
Inner member
Screws (B 4
x
6)
Screws (B 4
x
6)
L-angle
Rack
L-angle
Outer member
Bracket
50 mm
+
5
_
0
Содержание DVCAM DSR-60
Страница 2: ......
Страница 54: ......
Страница 174: ......
Страница 220: ......
Страница 236: ......
Страница 238: ...8 2 N DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 N DSR 60 80 ...
Страница 242: ...8 2 P DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 P DSR 60P 80P ...
Страница 284: ......