6-39
DSR-80/80P/60/60P
6-25. GUIDE ROLLER ASSEMBLY (TG-2) REPLACEMENT
Tools
Tape guide adjustment driver : J-6441-560-A
Cleaning cloth
: 3-184-527-01
Cleaning fluid
: 9-919-573-01
Removal
1. Remove the top flange by turning it in the
direction of arrow.
Note :
Do not turn the fixing screw which is
painted by screw locking compound.
2. Remove the guide roller assembly.
3. Remove the bottom flange and the compression
coil spring.
Attachment
4. Clean outside of the shaft of the S drawer arm
assembly with the cleaning cloth moistened with
cleaning fluid.
5. Insert the compression coil spring and the bottom
flange into the shaft.
6. Insert the new guide roller assembly into the
shaft in the direction as shown. (Fig.-1)
7. Revolve the top flange to attach it to the shaft.
8. Clean the guide roller assembly, top flange and
bottom flange with a cleaning cloth moistened
with cleaning fluid.
Adjustment After Replacement
9. Perform the Tape Path Adjustment.
(Refer to section 7-2.)
Note :
Be careful not to apply force to the S
drawer arm during removal and
attachment works. The external force to
the S drawer arm can give adverse effect
on the perpendicularity of the arm which
causes the tape path adjustment error.
a
b
a>b
Fig.-1
Top
Bottom
Top flange
Guide roller
assembly
Bottom flange
S arm assembly
Compression
coil spring
Shaft (cleaning)
S drawer arm
Содержание DVCAM DSR-60
Страница 2: ......
Страница 54: ......
Страница 174: ......
Страница 220: ......
Страница 236: ......
Страница 238: ...8 2 N DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 N DSR 60 80 ...
Страница 242: ...8 2 P DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 P DSR 60P 80P ...
Страница 284: ......