78
Appendix
Error Code List
When an error occurred in the S-AIT library, the Error/Warning LED lights in
orange. When an error occurred, check the error code appeared on the LCD
panel and then recover from the condition based on the list below. Afterwards,
turn off the power and then turn on the power again. When you turn on the
power yet the library is not initialized or an error still occurs after the
initialization, contact the Service and Support Center.
ERROR CODE
DESCRIPTION
SENSE KEY
To Recover
ASC
ASCQ
00
00
NO ADDITIONAL SENSE INFORMATION
There is no sense key to be reported.
NO SENSE
02
00
NO SEEK COMPLETE
The picker assembly element was not carried to
the specified position (Timeout in shipping).
HARDWARE
ERROR
Contact the Service and Support Center.
04
01
LOGICAL UNIT IS IN PROCESS OF
BECOMING READY
The unit is not ready (The mechanical part is
now working).
NOT READY
04
80
NOT READY, OPERATOR USING FRONT
PANEL
A user is now using the operation panel.
NOT READY
15
01
MECHANICAL POSITIONING ERROR
An error occurred in the picker assembly
element because top-and-bottom position was
improperly searched.
HARDWARE
ERROR
Contact the Service and Support Center.
15
80
MECHANICAL POSITIONING LIMIT ERROR
The limit of the bottom position with the picker
assembly element has been detected.
HARDWARE
ERROR
Contact the Service and Support Center.
15
81
MECHANICAL POSITIONING UNKNOWN
ERROR
An error occurred in the top-and-bottom
position with the picker assembly element.
HARDWARE
ERROR
Verify that the transport lock is detached
on the left side of the library.
1A
00
PARAMETER LIST LENGTH ERROR
Improper length of parameter list has been
detected when a data writing command was
issued by the initiator.
ILLEGAL
REQUEST
20
00
INVALID COMMAND OPERATION CODE
Detected that a command with unsupported
operation code was issued by the initiator.
ILLEGAL
REQUEST
21
01
INVALID ELEMENT ADDRESS
An improper element address has been
detected during the command operation issued
by the initiator.
ILLEGAL
REQUEST
24
00
INVALID FIELD IN CDB
An improper command field has been detected
during the command operation issued by the
initiator.
ILLEGAL
REQUEST
25
00
LOGICAL UNIT NOT SUPPORTED
An unsupported LUN has been detected in a
confirmation message or CDB.
ILLEGAL
REQUEST
26
00
INVALID FIELD IN PARAMETER LIST
An invalid parameter has been detected in the
parameter list.
ILLEGAL