39
Chapter 4 Commands
LIFE LOG DISP
This command is used to display life management data (operation counts) for
the library.
Press the “Enter” button when the command menu is displayed, and the LCD
panel display changes as follows. The library is now in Command execution
mode.
Display
Lower line: Displays life management data. PXX:YYYY
(X shows the page codes while Y shows the parameter pointers)
See “List of Life Management Data” below.
Button Operations
“Up” button:
Displays the next data.
“Down” button:
Displays the previous data.
“Enter” button:
No associated function.
“Cancel” button:
Returns to the command menu.
Page codes Parameter pointers
Descriptions
30h
0000h
The number of times that picker assembly
element was used to move cartridges.
0001h–0014h
The number of times that cartridges were
inserted into each store element.
0100h
The number of times that input/output
element (mail slot) was used.
0200h–0201h
The number of times that cartridges were
inserted in data transfer elements (drives).
31h
0000h
The number of times that cartridges were
inserted/ejected (mail slot).
0001h
The number of times that cartridges were
moved. (picker)
0002h
The number of times that picker assembly
element was moved. (slider)
0003h
The number of times that swinging
operations were executed.
32h
0000h
The number of times that the power was
turned on.
33h
0001h–0014h
The number of times that cartridges in each
slot were inserted in the drives.
LIFE DATA DISP
P30 : 0000 = 150