CDX-GT420U/GT424U/GT427UE/GT470U/GT470US
19
SECTION 4
DIAGNOSIS FUNCTION
Description of the Diagnostics function:
1. Setting the Diag display mode
With the power off, press the [4] button, [5] button, and [4]
button on the set body or the remote control (for more than 2
seconds) in turn.
2. Canceling the Diag display mode
During the Diag function mode, press the [OFF] button.
3. Initial display in the Diag display mode.
Just when the Diag mode is entered, “reset count” is displayed.
The display mode is switched by each rotation of [
M >/
SEEK +] or [
. m/
SEEK –] keys.
4. Contents of each display mode
4-1. Reset count display mode
4-2. Reset count by watchdog timer display mode
4-3. Number of connected units display mode
The display mode is switched by each rotation of [2/ALBM+] or
[1/ALBM–] keys during the number of connected units display
mode.
4-4. Operating hours display mode
Reset count display
OFFSET/FAILURE error display
CD error information display
Operating hours display
Number of connected units display
Reset count by watchdog timer display
9 9
9 9
9 9 9
9 9 9 9
9 9
9 9 9 9 9
USB error information display
9 9
Reset count
(in hexadecimal format)
Diag code
01: Reset count
9 9
Reset count
(in hexadecimal format)
Diag code
02: Number of resets by watchdog timer
9 9
Show the number of connected units for
CD-C, MD-C and XM respectively from
the rightmost (in hexadecimal format).
Recency of information
1-3: 1 represents the latest.
Diag code
03: Number of connected unit.
9 9 9
No. of connected units history 1 (latest) display
No. of connected units history 3 display
No. of connected units history 2 display
9 9 9
9 9 9
9 9 9
Operating hours
(in hexadecimal format)
Diag code
04: Operating hours
9 9 9 9