CDX-G1200U/G1201U/G1202U/G1280UM
5
1-2. Display in Destination Setting Mode
Note:
The displayed contents of the following
fi
gure is an example. The
destination code is different depending on the destination of the
product.
Destination code
OP0
OP1
OP2
OP3
OP4
OP5
6 digits
1-3. Entering the Destination Code
• Method of operation by main unit
1. Rotate the control dial, and select the alphanumeric character
of “0 to F”.
2. The digit advances by pressing the [PUSH ENTER/MENU] or
[
>
M
] button.
The digit returns by pressing the [MODE ] or [
m
.
] but-
ton.
3. The setting is completed by pressing the [PUSH ENTER/
MENU] button at the state of cursor position of “OP0”, then
the display turns off, the initialization operation is done, and
the display returns to the clock display.
• Method of operation by remote commander
(Except AEP, UK and HK models)
Note:
The model to which the remote commander is not attached can
also be operated by using the remote commander.
1. Press the [
V
] or [
v
] button, and select the alphanumeric char-
acter of “0 to F”.
2. The digit advances by pressing the [
b
] or [ENTER] button.
The digit returns by pressing the [
B
] button.
3. The setting is completed by pressing the [ENTER] button at
the state of cursor position of “OP0”, then the display turns off,
the initialization operation is done, and the display returns to
the clock display.
1-4. Destination Code
Model
Destination OP5 OP4 OP3 OP2 OP1 OP0
CDX-G1200U
US, CND
0
0
9
0
0
2
AEP, UK, HK
0
0
9
0
0
1
E, AUS
3
0
B
8
0
0
EA
2
0
9
8
0
4
AR
3
0
B
8
0
3
KR
3
0
9
8
0
0
IND
1
0
9
8
0
0
CDX-G1201U
AEP, UK
0
0
9
0
0
1
E
3
0
B
8
0
0
EA
2
0
9
8
0
4
KR
3
0
9
8
0
0
CDX-G1202U
AEP, UK
0
0
9
0
0
1
EA
2
0
9
8
0
4
CDX-G1280UM IND
1
0
9
8
0
0
2. Con
fi
rmation After Destination Setting
Execute the following operation after completing the destination
setting, and con
fi
rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons in
order of the [ 4]
t
[5]
t
[
u
6] (press only the [
u
6]
button for two seconds).
Clock display
2. In the state in which the software main version is displayed on
the liquid crystal display (refer to the following
fi
gure), enter
the destination setting value display mode by pressing the [
SCRL DSPL] button twice (software main version
t
soft-
ware DSP version
t
destination code).
(Displayed characters/values in the following
fi
gure are ex-
ample)
Software main version
3. Con
fi
rm the alphanumeric character of 6 digits on the liquid
crystal display is a value correctly input.
Note:
The displayed contents of the following
fi
gure is an example. The
destination code is different depending on the destination of the
product.
Destination code
OP0
OP1
OP2
OP3
OP4
OP5
6 digits
4. The resetting operation is executed by pressing the [ OFF
SRC] button for 1 second after the con
fi
rming ends, and the
unit returns to the normal condition.
Display after reset
Содержание CDX-G1200U
Страница 39: ...MEMO CDX G1200U G1201U G1202U G1280UM 39 ...