CDP-C360Z/CE415
RF PLL Free-run Frequency Check
Procedure :
1.
Connect frequency counter to test point TP (PLCK) with lead
wire.
2.
Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
Adjustment Location :