Cross Remote Features
of
mode
NT
ection
In NT mode, transmitters and receivers communicate via the Remote Control Unit RMU-01 connected to a
network. This enhances convenience during simultaneous multi-channel operation.
In ST mode, a paired receiver and transmitter operate in a one-on-one configuration. This will lead to channel
congestion when the equipment count increases. In NT mode on the other hand, the transmitter and receiver
communicate via the RMU-01. Because the RMU-01 controls the overall communication volume on the remote
control channels, congestion can be avoided also when equipment count increases.
NT Mode Features
Features of Remote Control Unit RMU-01
Connection diagram (simplified)
Connection to receiver is established via Ethernet (wired LAN).
By installing the Wireless Studio application (supplied with DWR-R01D) on a computer and connecting this
computer to the network, multiple transmitters can be monitored and controlled from the computer.
Computer used for monitoring
Hub
RMU-01
Up to 9 units can be
connected
Receiver
Up to 41 units can be connected
General communication flow
In NT mode, the receiver and transmitter communicate via the RMU-01, as shown below.
Communication flow from DWR-R01D
Computer used for monitoring
RMU-01
Send command
via Ethernet
Transmit control command
via 2.4 GHz band
Send information
as metadata via
UFH band
ATT 0 dB
Receive command and
change ATT to 3 dB
Show transmitter information
ATT 0 dB
Change transmitter attenuation to 3 dB
Update transmitter information
ATT 3 dB
Hub
Receiver
Transmitter
Technology