1-14 (E)
BDX-N1000
1-8. Error Message
Result of the self-diagnosis is displayed on the display of the front panel as the error message.
Message
Meaning
Measure
“MEM NG”
An error has occurred during the D-RAM check.
Check peripheral of IC703 (F-1) and
IC704 (F-2) on the IF-694 board.
“NG: DPRAM” An error has occurred during the dual port RAM check.
Check peripheral of IC502, IC503 (E-5),
IC1402 and IC1403 (E-6) on the IF-694
board.
“NG: NONRT” An error has occurred in the CPU data transmission
Check peripheral of IC500 (D-5), IC502,
and reception circuit.
IC503 (E-5), IC1401 (D-6), IC1402 and
IC1403 (E-6) on the IF-694 board,
and optional board.
“PROTECT!”
The write protect function of the FLASH ROM (CH0)
Set S600-8 (A-1) on the IF-694 board to
is enabled.
OPEN (upper position).
“Copy NG”
Contents of the IC card do not agree with those of
Check peripheral of IC705 (F-1),
the FLASH ROM.
IC706 (F-2), IC707 (G-1), and IC708 (G-2)
on the IF-694 board.
1-8. Error Message