background image

Troubleshooting

Symptom:

Device remains 'OFF'

Make sure that the power cord is securely seated in the IEC socket and plugged all the way into the AC outlet.

Make sure that the AC outlet is live (check with tester).

Remove power cord and check the Fuse. If blown, then replace with exact type and rating.

Symptom: 

Device is 'ON' but no audio output

Is the master level control on the front panel turned up? The gain control on the rear panel may be at minimum position.

Is the signal source turned up? Make sure that the signal level from the device preceding the SM 50Ak is high enough to 

match the Input sensitivity (Gain control on rear panel).

If either stereo pair is not producing sound, then switch the signal around. If the problem also switches sides, the problem is 

not the monitor. It could be a bad signal cable, or no signal from the mixer.

Symptom:

 Distorted 

sound

Ensure secure connectivity of the TRS / XLR. 

Reduce signal level at mixer or reduce gain control of SM 50Ak at rear panel.

Please monitor the signal with headphones. Distorted sound in headphones indicate that the problem lies in the signal 

source.

Symptom: 

Noise / Hum / Line interference

Proper signal wiring between the mixer and the monitor eliminates the hum, buzz and all sorts of crackling noises. Make sure 

all connections are secure.

If unbalanced sources are used, wire the connectors such that the unbalanced ground of the source is connected to the 

inverting pin (pin 3 for XLR, ring for TRS jack) and ground (pin 1 for XLR, sleeve for TRS jack).  Improper cabling will result in 

unsatisfactory audio reproduction. (please refer to Fig. 5 on page 4)

If a CATV cable is connected to the system, and a persistent mains hum occurs, disconnect it. If the hum goes away call the 

cable operator to check for proper cable grounding methods. Using BALUN transformers (1:1, isolated type) might solve the 

problem.

Make sure that the signal cable is not routed near AC cables. 

If a light dimmer or triac-based device exists on the same AC circuit as the monitor, buzzing noises may occur. AC Line filters 

may eliminate the problem.

Page 5

S

N

O

D

N

Y E

O

SM 50Ak

Содержание SM 50Ak

Страница 1: ...SM 50Ak 2 way nearfield active monitor owners manual www sonodyne com S NOD N Y E O S NOD N Y E O ...

Страница 2: ...exposure may cause permanent hearing damage Ensure that the speakers are not covered while in use Restricted airflow at the rear of the unit will cause it to heat up UNPACKING While removing the units from the carton please do not hold the speaker s front The high frequency transducer is located near the top of the cabinet on the front baffle you may accidentally damage the transducer The best way...

Страница 3: ...ise the overall output level permitting LOUD mixing But keep in mind that removing deep bass content from monitors may actually result in an inaccurate bass reproduction ROOM COMPENSATION LF BASS TILTS Switches 2 3 when ON activates a filter 80 Hz to reduce the low frequency output by 2 dB 4 dB respectively Engaging both switches produces a 6 dB roll off These functions can be used to compensate f...

Страница 4: ...le should be around 60 as shown in Fig 4 on page 4 MOUNTING OPTIONS The SM 50Ak may be wall table or floor mounted Optional accessories are available CONNECTORS Audio The SM 50Ak has one balanced TRS and one 3 pin balanced XLR input refer to Fig 2 rear panel on page 1 The pin configuration is shown in Fig 5 on page 4 The wiring configuration for using unbalanced sources is also shown Please note t...

Страница 5: ...tening position Note Your SM 50Aks achieve their best bass response in a room that is optimized for bass reproduction Factors such as room shape and volume absence of acoustical treatment can prove to be a bane for optimal sound reproduction from the SM 50Aks Therefore we have provided some compensation controls which you can use to optimize the frequency response of the speakers for any particula...

Страница 6: ... control of SM 50Ak at rear panel Please monitor the signal with headphones Distorted sound in headphones indicate that the problem lies in the signal source Symptom Noise Hum Line interference Proper signal wiring between the mixer and the monitor eliminates the hum buzz and all sorts of crackling noises Make sure all connections are secure If unbalanced sources are used wire the connectors such ...

Страница 7: ...S NOD N Y E O SM 50Ak Page 6 Fig 6 7 8 FIG 7 FIG 6 FIG 8 ...

Страница 8: ...COMPLEMENTS ENCLOSURE TYPE OVERALL FREQUENCY RESPONSE USABLE FREQUENCY RANGE MAX LONG TERM SPL HALF SPACE HORIZONTAL BEAM WIDTH VERTICAL BEAM WIDTH TOTAL HARMONIC DISTORTION AMPLIFIER POWER BEFORE CLIPPING S N RATIO AT UNITY GAIN AMPLIFIER THD AT RATED POWER INPUT LEVEL FOR 109 DB SPL AT 1M GAIN CONTROL RANGE VOLUME CONTROL RANGE CMRR SUBSONIC FILTER CROSSOVER BASS TILT BASS ROLL OFF TREBLE TILT C...

Отзывы: