Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 

 

 

 

Operation and Maintenance Documentation 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

SONNIGER Polska Sp. z o.o. Sp.K.

 

ul. Śląska 35/37, 81-310 Gdynia, Polska, 

infolinia 801 055 155

, tel. + 48 58 785 34 80

www.sonniger.com

 

Sąd Rejonowy Gdańsk-Północ, VIII Wydział Gospodarczy Krajowego Rejestru Sądowego, KRS 0000504509, 

NIP 586 227 35 14,Regon 22154369 k

apitał zakładowy: 1.655.000 PLN 

Содержание GUARD PRO

Страница 1: ...nance Documentation SONNIGER Polska Sp z o o Sp K ul Śląska 35 37 81 310 Gdynia Polska infolinia 801 055 155 tel 48 58 785 34 80 www sonniger com Sąd Rejonowy Gdańsk Północ VIII Wydział Gospodarczy Krajowego Rejestru Sądowego KRS 0000504509 NIP 586 227 35 14 Regon 22154369 kapitał zakładowy 1 655 000 PLN ...

Страница 2: ...ition surfaces 2 BASIC TECHNICAL PARAMETERS GUARD PRO PARAMETERS GUARD PRO Curtain with water heater Curtain with electric heater Curtain without heater GUARDPRO 150W GUARDPRO 200W GUARDPRO 150E GUARDPRO 200E GUARDPRO 150C GUARDPRO 200C Length of unit m 1 5 2 1 5 2 1 5 2 Max airflow range m 7 5 7 5 7 5 Heat output kW 33 47 14 17 5 Max air output m h 6 500 3 700 2 400 9 000 5 150 3 450 6 700 3 800 ...

Страница 3: ...very In the absence of any element please fill in the suitable carrier document NOTICE Do not use the curtain in rooms containing any flammable and or combustible substances biological substances or in environments with corrosive air components Do not use the curtain in rooms with relative humidity above 80 Do not leave the curtain ON unattended for longer periods Do not use the curtain without pr...

Страница 4: ...way If you decide on ACTIVE PROTECTION system which is the assembly of curtains with water exchanger and without one you have to mount air curtains with water exchangers on the bottom When connecting the curtain make sure that maintenance work is possible to be conducted On both connection nozzles manual shut off valves should be installed in case of the necessity of disconnecting the unit The hot...

Страница 5: ... assembly To mount the curtain vertically make sure the air outlet of the curtain is as close as possible to the doorway and air gap is at the height of the upper edge of the entry Please make sure to keep the distance of about 300 mm between the outlet casing and the wall To mount two GUARDPRO curtains one above the other it is necessary to use the GUARDPRO multi purpose connector to install the ...

Страница 6: ... are not included in the set Also the DOORSTOP door contact switch can be installed it turns off the GUARD PRO curtain when the door is being closed and the moment the door is being opened the GUARD PRO curtain starts operating accordingly to the parameters set in the control panel of the device Fan wiring description U1 high speed brown U2 middle speed grey U3 low speed red N neutral blue PE prot...

Страница 7: ...NNECTION SCHEME FOR GUARD PRO TYPE W WATER EXCHANGER TYPE C AMBIENT WITH PANEL COMFORT ONLY 1 UNIT FOR COMOFORT PANEL Power supply cables not included 7 2 CONNECTION SCHEME FOR GUARD PRO TYPE E ELECTRIC HEATER WITH PANEL COMFORT ONLY 1 UNIT FOR COMOFORT PANEL Power supply cables not included ...

Страница 8: ...202106 7 3 CONNECTION SCHEME FOR GUARD PRO TYPE W WATER EXCHANGER TYPE C AMBIENT WITH A CONTROL BOX MADE BY INSTALLER Power supply cables not included 7 4 CONNECTION SCHEME FOR GUARD PRO TYPE E ELECTRIC HEATER WITH A CONTROL BOX MADE BY INSTALLER Power supply cables not included ...

Страница 9: ...n and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 7 5 CONNECTION SCHEME FOR GUARD PRO TYPE E ELECTRIC HEATER WITH THE MULTI 6 CONTROL BOX UP TO 6 UNIT Power supply cables not included ...

Страница 10: ...aintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 7 6 CONNECTION SCHEME FOR GUARD PRO TYPE W WATER EXCHANGER TYPE C AMBIENT WITH THE MULTI 6 CONTROL BOX UP TO 6 UNIT Power supply cables not included ...

Страница 11: ...tention when cleaning the exchanger s fin due to high possibility of damaging them If the fin is bent use a special tool If the device has not been used for a longer period of time unplug it before the next use The heat exchanger is not equipped with any anti freeze protection device The heat exchanger may be damaged if the room temperature goes below 0 C If the device is to operate in a room wher...

Страница 12: ...TC optional WARNING RISK OF ELECRICAL SHOCK Disconnect power supply before making any electrical connections Contact with components carrying hazardous voltage can cause electrical shock and may result in severe personal injury 1st Prędkość pracy wentylatora bieg 1 2 3 lub automatyczny 2nd Temperatura pomieszczenia 3rd Symbol zabezpieczenie przeciwzamrożeniowe 4th Programowanie automatyczne 5th Us...

Страница 13: ...nd hold both of them for 5 seconds Press MODE Change on manual mode or automatic mode Hold MODE for 5 seconds Change to cool mode heating mode ventilation mode Press FAN Change of the fan speed to low medium high automatic Hold FAN for 5 seconds Manual calendar programming Monday Friday Saturday Sunday 6 settings per day BMS Functions Setting Reading to work parameters Work Stop conditions Weekly ...

Страница 14: ...r covers 24 months The guarantee period commences upon delivery of the device to the Buyer specified in the sales invoice The warranty covers any and all parts components specified in the scope of the delivery 5 Products delivered by third persons are guaranteed by this supplier 6 Devices may be started and serviced only by qualified persons trained in the areas of maintenance and operation of the...

Страница 15: ... device is installed by the installing contractor to avoid low temperatures on electrical and mechanical parts such as valves electric and electronic controlling devices water condensation and frost ice near the device thermal shock of the heater and heat exchanger caused by sudden changes of outside temperature 3 SONNIGER is not liable to 1 Current maintenance works inspections following from Ope...

Страница 16: ...RD INVESTMENT NAME UNIT TYPE UNIT NUMBER PURCHASE DATE STARTUP DATE INSTALLATION COMPANY DATE NAME OF STARTUP INSTALLER COMPANY NAME ADDRESS PHONE SIGNATURE OF STARTUP INSTALLER MAINTENANCE AND REPAIR REGISTRATION Date Maintenance and repair description Stamp and signature of installation company ...