Sonnenkraft KIOTO SOLAR Glas-60 framed Series Скачать руководство пользователя страница 3

 

Seite 

3

 von 

12

 

KIOTO_Installation_manual_2021                                                         © KIOTO Photovoltaics GmbH, Solarstraße 1, 9300 Sankt Veit/Glan - Österreich  06/2021

 

 

Please read these installation instructions carefully before installing the photovoltaic modules. 
The non 

– observance could lead to damage to persons and / or goods. Further the guarantee 

and the product warranty could expire. The installation of photovoltaic modules requires 
technical knowledge; therefore, this must be done by skilled and qualified persons! 

The general handling of the product, the using and the exact installation are beyond the 
control area of KIOTO Photovoltaics GmbH. Therefore, KIOTO cannot take responsibility for 
any damage, loss or cost which is caused by inappropriate installation, inappropriate handling 
of the product or wrong use! 

General module handling 

  Do not open or demount the module. 

  Do not remove any parts from the module. 

  Do not remove or damage any product markings. 

  Do not stand or step on a module to prevent the risk of injury and damage to the module. 

  Do not drop the module. 

  Avoid any form of external force exposure. 

  Do not expose the module, especially the module backside to any lacquer, paint, glue, 

chemicals or other abrasive liquids. 

  Do not handle the module at the junction box. 

  Do not pull the module connection cables by forces. 

  Do not drill any holes in the framework or other components of the module. 

  Do not interfere with the internal electrical connection of the module. Contact your photovoltaic 

retailer if problems occur. 

  Please consider the maximum system voltage. 

  Never align simulated sunlight on the module or parts of the module. 

  Observe the mounting and installation instructions of other used components. 

  Prior to the installation of the modules, please contact the appropriate authorities to determine 

the necessary requirements regarding installation, approval and inspection. 

Product marking, product label 

  The product label is placed on the backside of the module and contains all required important 

electrical and product specific values. The information on the label relates to EN 50380:2003 
and Standard Test Conditions (1000W/m² - 25°C 

– AM 1,5). 

  Electrical and mechanical characteristics can be taken from the current data sheets. These 

are available in the download area at 

www.kiotosolar.com

. 

The product label must not be damaged or removed 

– otherwise the guarantee and product 

warranty will be invalidated! 

Technical data 

Module series:  

KPV ME NEC 

– 320/325/330/340/380Wp 

  

 

 

KPV GME/GML (framed/unframed) NEC 

– 310/360Wp 

  These modules are configured for use in DC systems. 

Содержание KIOTO SOLAR Glas-60 framed Series

Страница 1: ...PHOTOVOLTAIC MODULES Installation manual Power 60 Standard MAXIM ALPIN Glas 60 with without frame Project 60 halfcut...

Страница 2: ...ctions for mounting 4 Electrically 4 Mechanically 5 Advices double glass modules without frame 5 Fixing points of the KIOTO modules 6 Electrical connection of the photovoltaic generator 6 Detailed inf...

Страница 3: ...or other abrasive liquids Do not handle the module at the junction box Do not pull the module connection cables by forces Do not drill any holes in the framework or other components of the module Do...

Страница 4: ...e followed stringently Remember in de energized state high contact voltage could occur and or deadly electric arc can be generated Cover the single module with a lightproof material during the mountin...

Страница 5: ...of application Ensure that there is adequate ventilation behind the modules To generate optimal output of the photovoltaic generator consider the perfect alignment and mounting angle of the photovolta...

Страница 6: ...be securely fastened with continuous support profiles at least 4 points The PV modules can only be attached to the substructure by clamping from the front The clamping area must be at least 400 mm per...

Страница 7: ...se high quality cables to assure a failure free operating Ensure good isolation and whether UV durability of the cables The rated voltage of the solar cable must be 1000V minimum If possible use flexi...

Страница 8: ...be done by qualified persons to ensure an optimized energy yield For safety reasons and to minimize maintenance works a DC disconnector should be installed between the generator and the inverter This...

Страница 9: ...n in performance Clean the modules as required and soiled with plenty of water and a soft cloth or sponge without any detergent Do not use high pressure cleaners If other additives or devices like agg...

Страница 10: ...Seite 10 von 12 KIOTO_Installation_manual_2021 KIOTO Photovoltaics GmbH Solarstra e 1 9300 Sankt Veit Glan sterreich 06 2021...

Страница 11: ...Seite 11 von 12 KIOTO_Installation_manual_2021 KIOTO Photovoltaics GmbH Solarstra e 1 9300 Sankt Veit Glan sterreich 06 2021...

Страница 12: ...KIOTO Photovoltaics GmbH Solarstra e 1 Industriepark A 9300 St Veit Glan T 43 0 4212 28 300 0 E office kioto com www kiotosolar com...

Отзывы: