Common Online Failures and Countermeasures
The MP5S Plus Writer prompts for different types of failures in online mode;
For different information, the countermeasures are shown in the following table:
No.
Type and information of failure
Countermeasure
1
Error: USB Device is Not detected!!!
A: Ensure the USB cable is well connected with the computer and the
writer;
B: Change to other USB interfaces of the computer;
C: Change the USB cable.
2
MCU Type and the writing file are inconsistent!!!
Please try again!!!
Please confirm the type of selected MCU and the writing file are
consistent, and then redownload the writing file;
3
Incorrect writing file!!!
A : Check the writing file or the setting of Rolling
Code!!!
B : Please redownload the writing file!!!
Please confirm whether the setting of Rolling Code in the source code
is consistent with the INI file;
4
VXX or VPP Error!!!
A : Check VXX and VPP of MP5S Writer!!!
B : Check MCU Placement Direction!!!
A: Please remove MCU , and power on again;
B: Remove MCU , if there is still the prompt, please contact with the
supplier or SONiX;
6
Cannot find MCU!!!
A: Please check Text tool!!!
b: Check MCU model and placement direction!!!
A: Please place MCU ;
B: MCU of other model is placed , please replace;
C: MCU placement or direction is incorrect;
D: There are open/short-circuit and other problems in some pins of the
placed MCU;
7
Please check MCU Model!!!
Place MCU of other model;
8
Blank check failure!!!
Please confirm the used MCU is blank;
9
A: Erase failure!!!
B: Return signal failure!!!
C: Write program failure!!!
D: Read ROM failure!!!
E: Read Flash failure!!!
F: IHRC Correction failure!!
G: Compare checksum failure!!!
A: Confirm that MCU is well contact with the MP5S Writer;
B: Confirm that the used cable is shorter than 15cm;
C: Confirm the used socket is in good contact, please clean and replace
regularly;
D: Whether the pins of MCU have open/short circuit;
If there is still problem, please contact with the supplier or SONiX;
10
Verify failure!!!
A: Confirm the writing file is consistent with the data of MCU to be
written;
B: Confirm that MCU is well contact with the MP5S Writer;
C: Confirm that the used cable is shorter than 15cm;
D: Confirm the used socket is in good contact, please clean and replace
regularly;
E: If there is still problem, please contact with the supplier or SONiX;