xvi
Redbox RB-SC2 User Handbook
TECHNIC
AL SPECIFIC
A
TION
3
10
TECHNICAL SPECIFICATION
Error messages
The following error messages can be returned for illegal commands
Err:01
- return if Command Not Found
Err:02
- return if Missing Parameter
Err:04
- return if Parameter out of range
Upgrading Firmware
Occasionally, it may be necessary to upgrade the firmware on the RB-SC2 to add new
functionality and fix software bugs. New firmware updates will be made available from time
to time on the Sonifex website. Visit www.sonifex.co.uk for details.
The firmware is upgraded using the Serial Control Interface - SCI. This PC software
downloads the new firmware and initiates the upgrade process. To upgrade the firmware,
select the required firmware file in the SCI upgrade firmware section. The RB-SC2 will
automatically reboot and enter the bootstrap mode prior to the transfer of the firmware file.
The SCI software downloads the firmware to internal memory, and then erases the current
firmware before programming the update. When the firmware is complete, the unit reboots
with the new firmware.
Please note: Firmware files can take several minutes to transfer to the RB-SC2 at lower
baud rates. To speed up the process, select a higher baud rate prior to transferring the new
firmware.
Technical Specification RB-SC2
Connections
Digital Inputs:
2 x AES/EBU XLR 3 pin female
2 x S/PDIF RCA phono
2 x TOSLink optical input
Digital Outputs:
2 x AES/EBU XLR 3 pin plug
2 x S/PDIF RCA phono socket
2 x TOSLink optical output
Sync Inputs:
1 x AES/EBU XLR 3 pin female
1 x Word Clock BNC
1 x Video Input (optional)
Video Sync Specs:
The Digital video sync board will accept 270Mbps SD-SDI
and HD-SDI signals covered by SMPTE-259-M-C (SD) and
SMPTE-292M (HD).
The Analogue video sync board will accept a composite
signal of NTSC (525), PAL (625) & SECAM (625) signals
covered by SMPTE-170-M (NTSC) and ITU-R BT.470-6 (PAL &
SECAM).