1-2
(b). Press the power OFF key
to cut the power supply.
Note: If you cut the power switch without storing the transducer, the storage
operation of the transducer is automatically performed by the “Automatic
ascent operation”. After storing the transducer up to the upper limit, the
power supply is automatically shut off. In addition, when cutting the power
supply for safety, cut the power supply after storing the transducer.
1. 2. 2. Descent and Ascent of Transducer
(1)
Project transducer
Press the descent key
of the controller to lower the transducer.
During the descent of the transducer, the hoisting amount display bar
located in upper right of the screen is filled in proportion to the
hoisting amount and the upper lamp of the descent key
flashes
on and off. Further, d
uring the hoisting operation, “
↓
” is indicated on
the left of the hoisting amount display. When the operation is performed up to the lower
limit, the hoisting amount display bar is completely filled in and the upper lamp of the
descent key
flashes on. The message for the lower limit is indicated on the screen.
Perform the descent operation for the hoist unit at a ship speed of 15 knots or less.
When the hoisting amount increases to 40% or more, transmission is automatically
started by the “Auto TX” operation. (Enabled when “Menu” – “Horizontal Sonar” – “TX”
setting is “Auto”)
(2) Store the transducer
Press the ascent key
of the controller to store the transducer.
During the ascent of transducer, the length of the hoisting amount display bar located in
upper right of the screen is reduced and the upper lamp of the ascent key
flashes
on and off. Further, during the hoisting operation, the arrowhead “
↑
” is indicated on the
left of the hoisting amount display.
When the operation is performed up to the upper limit, the hoisting amount is indicated
as completely empty and the upper lamp of the ascent key
flashes on. Further, a
message of the upper limit is indicated on the screen.
Perform the ascent operation of the hoist unit at a ship speed of 15 knots or less. When
the hoisting amount decreases to 40% or less, transmission is automatically stopped by
the operation of “Auto TX”. (Enabled when “Menu” - “Horizontal Sonar” - “TX” setting is
“Auto”)
Содержание KCS-5200
Страница 1: ...Model KCS 5200 Color Scanning Sonar Operation Manual Ver 1 48 E Rev 0...
Страница 2: ......
Страница 14: ......
Страница 22: ...2 4...
Страница 28: ...3 6...
Страница 46: ...5 12 A display example of Net Cast Net Set and VRM Wake Net Cast mark Net Set ring mark VRM VRM distance...
Страница 50: ...5 16...
Страница 78: ...6 28 Menu Screen Sub Screen Orthogonal Display Axis...
Страница 80: ...6 30...
Страница 84: ...7 4...
Страница 90: ...8 6...
Страница 106: ...9 16...
Страница 116: ...10 10...