Warning transmitter module for 5 different areas and general calls. Normally 
used in combination with the PCP1251 or PCB1210 warning receiver control 
devices, with two objectives: 1- Central warning transmitter.
2- Radial or ring intercommunication (see diagrammes).
Can also be used as an independent warning transmitter centre, but in this 
case without any background music or warning reception in said centre. 
(see attached diagramme)

When connected to a warning receiver control device, a call should be made 
to this area to check that that the warning is heard correctly.

During the reception of the warning, the warning reception indicator (6)
Should light up.

To send a warning just push down on any of the area buttons 
(1,2,3,4 or 5) or the general call button (5) and speak at a distance of 
between 30 to 40 cm. from the microphone (7).

The microphone level (9) has already been factory adjusted to this distance, 
but this can be modifi ed by the user to adjust the same to their particular 
requirements. Warnings can only be transmitted when the Line Engaged 
LED (6) is off

WARNING: The system cabling should be installed separately from 
the mains electricity supply in accordance with regulations.

Supply voltage 16 V DC
Maximum consumption (transmitting calls) : 50 mA 
Microphone: Unidirectional directivity
Frequency response:  90 Hz - 16 KHz. 
Audio output level (Terminal 7): 3V
Nominal input level for warning switching: 15V                  
Nominal output level for calls (general and areas): 15V

Dimensions (L x H x D): 45x45x27 mm. 
Weight:  50 grammes

Keypad for calls to 5 different areas.
Separate button for a general call to the entire installation. 
Line Engaged indicating light.
High sensitivity microphone incorporated with output level adjustment

Before connecting the device, ensure that it is not connected to the mains 
supply. Insert the control in the metal chassis and connect up in accordance 
with the following instructions:

TERMINALS

2

3/9S

4

 

7

 

Z1

 

Z2

 

Z3

 

Z4
Z5

8

9R

 

9E 

  

WARNING TRANSMITTER MODULE

 - PCB1350

GENERAL CALL MORE THAN 5 INDEPENDENT AREAS

4FA035001

 

DESCRIPTION

-
-
-
-

 

GENERAL CHARACTERISTICS

 

CONNECTION

Input +16V Supply
Transmission/reception of warning control output. For connection 
to the 9R terminal of the attached control device (when connected 
to a warning reception control device)
Earth
Audio warning Input/Output
Call to Area 1 output (connect to Area 1 wire)
Call to Area 2 output (connect to Area 2 wire)
Call to Area 3 output (connect to Area 3 wire)
Call to Area 4 output (connect to Area 4 wire)
Call to Area 5 output (connect to Area 5 wire)
Area select input. Connect to assigned area wire Zx (when con-
nected to a warning reception control device)
General call input. Connect to wire 9 (when connected to a warning 
reception control device 
General call output. Connect to wire 9 to transmit a general call or 
with wire Z0 for star intercommunication.

 

OPERATION

 

TECHNICAL CHARACTERISTICS

1 – Call to Area 1 button.   2 - Call to Area 2 button.   3 

- Call to Area 3 button.    4 - Call to Area 4 button. 5 

– General call button. 6 – Line Engaged indicating light.  7 

- Microphone.   8 - Call to Area 5 button.   9 – Microphone 

adjustment level.

.