USER MANUAL
13
light. Turning it on is executed by pressing (18) button. Pressing the (18) button again will
increase the intensity of the flashlight brightness (3 levels) up to its maximum level. Press-
ing the (18) button further will repeat the sequence (turned off - level 1 - level 2 - level 3 -
turned off - ...etc.)
Information about the flashlight status and its current brightness level is displayed as an
icon in the low right corner of the screen. Enabling the flashlight and changing its bright-
ness can also be executed by clicking its icon on touch screen with pen.
This function is available when activated in the system settings menu (see section 8.3).
4.7. Manual calibration
During operation, the camera runs periodic auto-calibration procedure (it is signalled by
the closing shutter sound and the "Calibration" word appearing on the bottom of the
screen). Calibration can also be triggered manually at any time. while being in real time
mode (with infrared thermal image being displayed), press and hold
button for 2 sec-
onds..
4.8. Selecting the colour palette
Color palette corresponding to the temperature values can be changed in every mode.
Select palette option in the Menu.:
or click on the temperature bar on screen and a window with the selection of 8 palettes
will pop up on.
Palette selection is made by clicking on chosen palette bar. After selecting desired palette
click once again on the temperature bar or press
button (6). Palette no.2 is set by de-
fault.
Содержание KT-640
Страница 1: ...USER MANUAL THERMAL IMAGER KT 640 SONEL S A ul Wokulskiego 11 58 100 widnica version 1 1 09 09 2014...
Страница 14: ...SONEL KT 640 THERMAL IMAGER 14 Available colour palettes 1 2 3 4 5 6 7 8...
Страница 39: ...USER MANUAL 39 Go to Start menu or select Network Connections in Control Palen and select Network Connections...
Страница 47: ...USER MANUAL 47 Type in IP address as below Press ok and data from the camera can be transferred to computer...
Страница 49: ...USER MANUAL 49 3 in the next window select General and then Restart now 4 go to Troubleshoot...
Страница 50: ...SONEL KT 640 THERMAL IMAGER 50 5 go to advanced options 6 select Startup settings...
Страница 54: ...SONEL KT 640 THERMAL IMAGER 54 And select an option as below...
Страница 58: ...SONEL KT 640 THERMAL IMAGER 58 Go to the bar in low right corner and select open Network and Sharing Center...
Страница 74: ...SONEL KT 640 THERMAL IMAGER 74 Size 186mm 106mm 83mm Standard Model Housing Magnalium Tripod interface 1 4 20...