L
N
16A
I max: 16A
This control is not a safety device, and can not be used as
such, it is the installer's responsibility incorporate
adequate protection for each type of facility
(Homologated).
Before opening the box, to access the connections, make
sure disconnect the power.
The power supply circuit should be provided with a
switch for disconnection of minimum 2A, 230 V, located
near the appliance. The cables must be enter through the
back and should be H05VV-F or H05V-K. The cable section
will depend on local regulations, but should never be less
than 1 mm. The cables for connecting the relay contacts
must have a section of 2.5 mm.
The equipment must be installed in a place protected
from vibrations, water and corrosive gases, where the
ambient temperature does not surpass the value in the
technical data.
The probe cable must be as far away as possible from
other electrical conductors. Its recommended by actual
normative that maximum length should not exceed 3
meters, and if it is necessary lengthen has to be done with
welding and shrink splice, to avoid reading errors.
4
- Very Important
Instructions for Installation and Use
Multiprobe Electronic Control NTC, PTC & contact closure
EC 230-331
Code 26.215
1
- Installation
Fit joint
Locate on the panel
Fix on the panel
Control manipulation should be carried out by
qualified technicians and probe cables should
NEVER
be installed together with power
cables, control or power.
Connect to the power supply
Mode Cool (P0=0)
ESC / key
Press for 5 seconds to start/stop Fast Freezing mode
(rapid cooling).
In the programming menu, exit without saving
parameter, return to previous level or exit
programming.
2
- Operation
1
ESC
FF
3
- Screen messages
SET key
Press for 5 seconds to modify the set point (SP).
Press for 10 seconds to go to the programming menu.
In the programming menu, go to the level displayed or
accept the new value while setting a parameter.
UP key
Pressing for 5 seconds activates Standby mode,
pressing for 2seconds returns the equipment to
normal mode. In Standby mode,the equipment
performs no actions and only the indicator is
displayed on the screen.
Pressing for 5 seconds starts/stops defrosting.
The programming menu, allows you to scroll through
the various levels or, during the setting of a parameter,
to change the value.
Down key
The programming menu, allows you to scroll through
the various levels or, during the setting of a parameter,
to change the value.
DEF. relay ON
Keys
FastFrezzing mode
Heating mode (P0)
Access code (Password) request.
Indicates a defrost is underway. (Only if
parameter d2=2)
Door open alarm (Only if P10 or P11=1 and as
per time at A12).
IFlashing: minimum temperature alarm on
probe 1 (A2).
Activates the alarm relay.
Defrost time-out alarm (only if parameter
A8=1).
Severe external alarm activated (only if parameter
P10 or P11=3).
Activates the alarm relay.
Flashing: maximum temperature alarm on
probe 1 (A1).
Activates the alarm relay.
External alarm activated (only if parameter
P10 or P11=2).
Activates the alarm relay.
Probe 1 faulty (open circuit, crossover, or
temperature value out of range depending on
the type of probe).
Activates the alarm relay.
Probe 2 faulty (open circuit, crossover, or
temperature value out of range depending on
the type of probe).
Activates the alarm relay.
Mode HEAT (P0=1)
230 V~ 50/60Hz
COOL
(P0=0)
RES.
(P0=1)
Acces to Setpoint and Programming
Change Setpoint
1
SET
SONDER
ESC
FF
1
SET
SONDER
ESC
FF
1
SET
SONDER
ESC
FF
Temperature
Indication
10 sec.
5 sec.
Release
SET
to access
the set point
Release
SET
to access
programming
1
SET
SONDER
ESC
FF
1
SET
SONDER
ESC
FF
Adjust new
setpoint value
press
SET
to confirm
1
SET
SONDER
ESC
FF
Temperature
Indication
Programming Menu (parameters)
SET
SONDER
ESC
FF
1
1
SET
SONDER
ESC
FF
SET
SONDER
ESC
FF
Find the menu
and enter with
SET
SET
SONDER
ESC
FF
1
Find the
parameter and
enter with
SET
Set new value
& confirm with
SET
Relay ON
Stand-by mode
OFF Control
Temperature in
°C Celsius degrees
°F Farenheit degrees
Cooling mode (P0)
1
SET
SONDER
ESC
FF
Temperature Indication
Electrical Drawing 331
1
L
N
COOL
LOAD
RES.
On power-up, the equipment will start up in Wizard
mode (P3 / 1 flashing), press or to select the
most appropriate application and press
SET
.
5
- Start-up
7
8
1
2
4
20
8
1
0
2
-18
4
20
0
0
0
3
10
4
20
30
1
0
4
0
4
20
8
1
0
5
3
24
20
8
1
0
6
12
24
20
30
1
0
21
96
0
99
1
0
37
-
-
-
-
1
Otherwise, enter programming to modify.
The wizard will configure the parameters of the
equipment for the chosen application (table "Default
settings by application"). The parameters have been
defined for the most common applications, check that
these parameters are adjusted to your installation.
PARAMETER
S
DEFAULT SETTINGS BY APPLICATION (InI)
1
: Multipurpose
2
: Frozen
3
: Fruits and vegetables
4
: Fresh fish
5
: Soft Drinks
6
: Bottle racks
7
: AC
8
: Heat / Incubators
Make connections according to label
Material included
Control
Sealing joint
Anchors to Fix panel
Manual
SET
ESC
FF
Probe
R. CARTER
12
11
10
9
Dl1
S2 / Dl2
S1
4
3
2
1
7
6
5
L
N
16A
I max: 16A
230 V~ 50/60Hz
L
N
R. CARTER
12
11
10
9
Dl1
S2 / Dl2
S1
4
3
2
1
7
6
5
L
N
16A
I max: 16A
230 V~ 50/60Hz
L
N
R. CARTER