SONARAY ST-5150 Скачать руководство пользователя страница 1

PRODUCT

PHOTO

MODEL 

NUMBER

ST-5150

ST-5300

POWER 

CONSUMPTION

148W

304W

OPERATING

VOLTAGE

100-277V AC ~ 50/60Hz

HOUSING 

MATERIAL

Aluminum

OPERATING 

TEMPERATURE

-40°C ~ +45°C / -40°F ~ +113°F

IP 

RATING

65

EPA

RATING

2.21 ft²

2.95 ft²

BUG 

RATING

B3-U2-G3

B4-U2-G4

WEIGHT

13.09

18.70

DIMENSIONS 

20.27 x 13.11 x 3.14

26.96 x 13.11 x 3.54

Shoebox Area Light Installation Guide

ATTENTION

INSTALLATION PREPERATION

1. Take out the luminaire from the box and place it on a level platform for easy installation.

2. For proper operation, a qualified electrician should perform the installation.

3. Ensure the normal ambient temperature of the installation location is between -40°C ~ +45°C.

4. Ensure the voltage of the luminaire is capatable with the onsite voltage before installation.

5. Any luminaire with damaged power cord should not be installed. 

Note: The power must be cut off before installation.

LIVE = BLACK

NEUTRAL = WHITE

GROUND = GREEN

TECHNICAL PARAMETERS

INSTALLATION DIAGRAM (PC - PHOTOCELL)

1. When the photocell function is required, the photocell should ne installed on the back of the fixture. When it’s 

not required, a shorting cap will be installed on the back of the lamp. 

REV: 21 0101 0000

TYPE

DATE

PROJECT

NOTES

www.sonarayled.com

®

©2021  |  SONARAY LED LIGHTING HEADQUARTERS  |  34 LAKEVIEW COURT VERONA, VA 24482 USA  |  OFFICE 844.202.5606  |  FAX 540.242.7221

This manual instructs the important information of installation and operation. Be sure to strictly follow 

the instructions before use. To ensure correct installation and operation of the product, carefully read 

and understand all contents of this guide. Any mechanical or electrical modifications to the product 

will void warranty and may cause dangerous hazards. To avoid potential issues caused by high 

temperature, be sure no objects are on the lens while the product is switched on.

GENERAL MAINTENANCE

Make sure there is no power running to the luminaire when performing maintenance. 

The lens and the housing can be cleaned using a soft cloth without any corrosive material. 

SITUATION

POSSIBLE REASON

POSSIBLE SOLUTION

LED 

DOES NOT 

LIGHT UP

Incorrect input wiring

Confirm wire colors

No power to the luminaire

Recycle power or check power connection

Incorrect voltage

Confirm voltage

LED 

FLICKER

Poor power connection

Check power connection

Input voltage fluctation

Confirm voltage

TROUBLESHOOTING

Отзывы: