2.6.
Recycling and disposal
If installed, the battery must be removed from the motorisation
before the latter is disposed of.
Do not dispose of used remote control or other
batteries, if installed, with household waste. They
must be taken to the relevant recycling points.
Do not dispose of the motorisation with household
waste at the end of its life. Return the motorisation to
its distributor or use your local authority's special
waste collection services.
3. USE AND OPERATION
3.1. Normal operation
3.1.1. Using Keygo io type remote controls
Complete opening
Press the programmed button to open the door fully.
Partial opening
Press the programmed button to open the door partially.
STOP
Closing
Stop
STOP
3.1.2. Obstacle detection operation
• When an obstacle is detected during opening, the door will stop then
close again.
• When an obstacle is detected during closing, the door will stop and
reopen.
When an obstacle has been detected, allow the door to open fully.
3.2. Specific operation
Depending on the additional devices installed and the operating options
programmed by your installer, the motorisation may operate in the
following specific ways:
3.2.1. Operation with a 3-button remote control
STOP
3.2.2. Operation with safety cells
An obstacle placed between the cells will prevent the door from closing.
if an obstacle is detected when the door is closing, the door stops then
reopens fully.
If an obstacle is detected when opening, the door will continue to open.
If the cells are blocked for 3 minutes or more, the system switches to
“wired dead man” operating mode. In this mode, a command via a wired
input causes the door to move slowly. The door moves for as long as
the command is issued and stops immediately when the command is
discontinued. The system switches back to normal operating mode as
soon as the cells are no longer obscured.
Attention
the "wired dead man" mode requires the use of a safety contact
(e.g. keyed reversing switch ref. 1841036).
3.2.3. Operation with orange flashing light
The orange light is activated 2 s before the door begins moving if the door
is in sequential mode with automatic closure aJer a time-delay.
3.2.4. Integrated lighting operation
Integrated lighting comes on with the motor, and goes out 60 seconds aJer
the motor has come to a complete stop.
If a remote control is programmed to control the lighting, it operates as
follows:
With a 2 or 4 button remote control
With a 3-button remote control
3
Copyright© 2018 SOMFY ACTIVITES SA. All rights reserved.
EN
Dexxo Smart io
Содержание DEXXO SMART io
Страница 2: ......